23
No.
Parts name
Shape
Part#
Flex Vent 2" Kit 25 Feet
EZ2FVK-1
①
Universal Rain Cap - LE
EZ2FVK-URC-1
②
Top Flex Support for EZ2FVK
EZ2FVK-TFS
③
25 Feet - Flex Pipe 2" - LE
EZ2FVP25-1
⑤
Base Junction Adapter Set
EZ2FVBJADS-1
⑥
Base Junction Support (w/o hole)
EZ2FVBJS-1
⑦
Flex Vent 2" Sleeve
EZ2FVS
⑧
Flex Vent 2" Rigid 45 Elbow Set - LE
EZ2FVR45ELB-1
⑨
Flex Vent 2" Gasket for EZ2FVK-1
EZ2FVK-1-G
8.Parts Lists
22
Step
Installation Procedure(ex. @Garage)
Necessary Tool
26 Extend the lower end of
"
⑦
Flex Sleeve"
to the sleeve clamp connector of the upper
portion of equipment.
Then secure with
"2×
⑩
Fastening Screws"
, and apply
"
⑪
Aluminum tape"
covering the
connecting part. Make sure that it is firmly fixed by pulling by hand.
※
Do not stretch the
"
⑦
Flex Sleeve"
where the screws are secured, it will weaken the
point where the screws are attached to the
"
⑦
Flex Sleeve"
.
Phillips head
Screwdriver
⑩
Fastening Screws
⑪
Aluminum tape
Step-3
(W
ork where equipment is installed)
Pay attention not to get injured from the sharp edge of
"
⑦
Flex Sleeve"
WARNING
【
Point
】
Check and see if
"
⑦
Flex Sleeve"
is firmly fixed.
7.Maintenance
・
The venting system must be examined periodically by a qualified service technician to check for any leaks
or corrosion.
・
Check and confirm that there is no tension to the flexible vent by hanging or suspending of anything.
・
When changing the water heater, change whole venting components to new ones.
Periodically check the following to ensure proper
operation of the water heater.
45
°
45
°
Sleeve Clamp
<EZTR40>
<EZTR50 75>
Connector
【
Point
】
Screw locations are within
these two degree.