3 | Product description

NORIS Automation GmbH

8 / 23

Instruction Manual VD61

Product description

Safety notes

 

Select the appropriate pressure transmitter with regard to scale 

range, performance, medium-contacting parts and specific 

measurement conditions prior to installing and starting the in-

strument

Otherwise the transmitter cand be damaged.

 

 

Observe the relevant national regulations and observe the ap-

plicable standards and directives for special applications (e.g. 

with dangerous media such as acetylene, flammable gases or 

liquids and toxic gases or liquids and with refrigeration plants 

or compressors).

If you do not observe the appropriate regulations, serious injuries 

and/or damage can occur!

 

 

Open pressure connections only after the system is without 

pressure!

Please make sure that the pressure transmitter is only used 

within the overload threshold limit all the time!

Observe the ambient and working conditions outlined in „Tech-

nical data”.

Observe the technical data for the use of the pressure transmit-

ter in connection with aggressive / corrosive media and for the 

avoidance of mechanical hazards. Open circuit before removing 

connector / cover.

Ensure that the pressure transmitter is only operated in accord-

ance with the provisions i.e. as described in the following in-

structions.

Do not interfere with or change the pressure transmitter in any 

other way than described in these operating instructions.

Remove the pressure transmitter from service and mark it to 

prevent it from being used again accidentally, if it becomes 

damaged or unsafe for operation.

Otherwise serious injuries may occur and the transmitter can be 

damaged.

 

 

Take precautions with regard to remaining media in removed 

pressure transmitter.

Remaining media in the pressure port may be hazardous or toxic!

 

3

3.1

NOTICE

 CAUTION

 CAUTION

 CAUTION

Содержание VD61

Страница 1: ...Instruction Manual VD61 NAN KD 0031 EN_V01 01 05 05 2021...

Страница 2: ...Issue NORIS Automation GmbH 2 23 Instruction Manual VD61 Issue Information on issue Document ID NAN KD 0031 EN Issue V01 01 Date April 2021...

Страница 3: ...f safety and warning notes 6 2 4 Scope of delivery 7 2 5 Accessories and spare parts 7 3 Product description 8 3 1 Safety notes 8 3 2 Scope of application 9 3 3 Measuring principle 9 3 4 Type code 9 4...

Страница 4: ...be per formed by qualified and authorised technical personnel in accordance with the relevant documentation especially the safety and warning in formation contained therein Make sure that no excess pa...

Страница 5: ...ts are stored correctly Refer to the correspond ing technical information for further information Disclaimer We review the contents of our technical documentation at regular intervals to ensure it agr...

Страница 6: ...n manual is the installation commissioning operation and maintenance of pressure transmitter series VD61 Further more this instruction manual also contains important troubleshooting infor mation Use o...

Страница 7: ...ssories and spare parts Available accessories Adapter with G male thread Attenuator with G male thread Pos Description Drawing no Order no 01 Adapter with G male thread 59 201 522004 02 Attenuator K6...

Страница 8: ...tter is only used within the overload threshold limit all the time Observe the ambient and working conditions outlined in Tech nical data Observe the technical data for the use of the pressure transmi...

Страница 9: ...tion and use For further information please read the technical data Measuring principle The pressure prevailing within the application is transformed into a stand ardised electrical signal through the...

Страница 10: ...le thread available see accessories Signal acquisition Standard measuring range See measuring range table Electrical output Output signal and maxi mum permissible load 4 20 mA 2 wire RA UB 8 V 0 02 A...

Страница 11: ...ion Group 1 Class B and interference immunity industrial environment Measuring range VD61 Code Measuring range Overload 1 0 1 bar 2 bar 1 6 0 1 6 bar 3 2 bar 2 5 0 2 5 bar 5 bar 3 0 3 bar 6 bar 4 0 4...

Страница 12: ...1 3 bar 8 bar 4M1 1 4 bar 10 bar Preferred types Features marked with a symbol at the end of the line are preferred fea tures If you select a preferred feature for each placeholder the device is spec...

Страница 13: ...allation and commissioning Tools and equipment Have the following tools and equipment ready for commissioning Open ended spanner spanner width 27 Screwdriver Make sure that the tools and equipment are...

Страница 14: ...14 23 Instruction Manual VD61 Dimensions A B C D E Side view A Cable gland M16 cable 5 10 mm B Terminal for cable up to 1 5 mm2 C 15 mm D G1 4 female thread E 146 mm B A C Top view A 40 5 mm B 20 mm...

Страница 15: ...commissioning 5 Instruction Manual VD61 15 23 E A B C D F E A B C D F Adapter with G male thread A 32 mm B 5 mm C 6 mm D G1 2 E WAF22 F Material 1 4435 Attenuator with G male thread A 32 mm B 5 mm C...

Страница 16: ...e instructions to install the pressure transmitter A Screw the pressure transmitter on the mounting surface Therefore two boreholes are located in the transmitter housing see next fig Pos F Therefore...

Страница 17: ...use the nut of the pressure transmitter see previ ous fig and not the transmitter housing When screwing do not cross the threads If you use an attenuator or an adapter screw it between the pressure tr...

Страница 18: ...itude Make sure that no moisture enters the cable end X1 X1 VD61 Connection diagram Follow the instructions to connect the cable to the pressure transmit ter A Loosen the two screws see next fig Pos A...

Страница 19: ...nstalled correctly moisture can enter the transmitter housing This may lead to incorrect measurement signal loss or may even damage the transmitter F Screw the covering onto the housing by using both...

Страница 20: ...voltage and the pressure supply Clean the instrument with a moist cloth CAUTION Do not touch the measuring material if used with media that may harm people Otherwise serious injuries can be the result...

Страница 21: ...turn delivery in the Section General information 4 Disposal of defective sensors Electric devices must not be disposed together with normal waste Dis pose the transmitters in accordance with local req...

Страница 22: ...rload caused by overpressure Replace instrument Signal span varies EMC interference sourc es in the environment for example frequency converter Shield instrument cable shield remove source of interfer...

Страница 23: ...Germany Phone 49 381 519944 0 Fax 49 381 519944 4 Email info noris automation de Web www noris group com NORIS Benelux B V Nieuwland Parc 10L 2952DA Alblasserdam Netherlands Phone 31 78 890 7550 Fax...

Отзывы: