NORIS VD61 Скачать руководство пользователя страница 20

6 | Maintenance

NORIS Automation GmbH

20 / 23

Instruction Manual VD61

Maintenance

This transmiter is maintenance-free. Repairs must only be carried out by 

the manufacturer. However, note the following instructions for cleaning, if 

the transmitter is damaged and you have to remove it or before you send it 

back to the manufacturer.

  ▪  Before cleaning, correctly disconnect the pressure transmitter from the 

supply voltage and the pressure supply.

  ▪  Clean the instrument with a moist cloth. 

CAUTION! Do not touch the 

measuring material, if used with media that may harm people. 

Otherwise serious injuries can be the result.

  ▪  Wash or clean the dismounted instrument before returning it, in order 

to protect persons and the environment from exposure to residual me-

dia. 

CAUTION! Residual media in dismounted devices could harm 

people and environment.

  ▪  Take sufficient precautionary measures.
  ▪ 

NOTICE! Do not use any pointed or hard objects for cleaning, as 

they may damage the diaphragm of the process connection.

6

Maintenance

Cleaning

Содержание VD61

Страница 1: ...Instruction Manual VD61 NAN KD 0031 EN_V01 01 05 05 2021...

Страница 2: ...Issue NORIS Automation GmbH 2 23 Instruction Manual VD61 Issue Information on issue Document ID NAN KD 0031 EN Issue V01 01 Date April 2021...

Страница 3: ...f safety and warning notes 6 2 4 Scope of delivery 7 2 5 Accessories and spare parts 7 3 Product description 8 3 1 Safety notes 8 3 2 Scope of application 9 3 3 Measuring principle 9 3 4 Type code 9 4...

Страница 4: ...be per formed by qualified and authorised technical personnel in accordance with the relevant documentation especially the safety and warning in formation contained therein Make sure that no excess pa...

Страница 5: ...ts are stored correctly Refer to the correspond ing technical information for further information Disclaimer We review the contents of our technical documentation at regular intervals to ensure it agr...

Страница 6: ...n manual is the installation commissioning operation and maintenance of pressure transmitter series VD61 Further more this instruction manual also contains important troubleshooting infor mation Use o...

Страница 7: ...ssories and spare parts Available accessories Adapter with G male thread Attenuator with G male thread Pos Description Drawing no Order no 01 Adapter with G male thread 59 201 522004 02 Attenuator K6...

Страница 8: ...tter is only used within the overload threshold limit all the time Observe the ambient and working conditions outlined in Tech nical data Observe the technical data for the use of the pressure transmi...

Страница 9: ...tion and use For further information please read the technical data Measuring principle The pressure prevailing within the application is transformed into a stand ardised electrical signal through the...

Страница 10: ...le thread available see accessories Signal acquisition Standard measuring range See measuring range table Electrical output Output signal and maxi mum permissible load 4 20 mA 2 wire RA UB 8 V 0 02 A...

Страница 11: ...ion Group 1 Class B and interference immunity industrial environment Measuring range VD61 Code Measuring range Overload 1 0 1 bar 2 bar 1 6 0 1 6 bar 3 2 bar 2 5 0 2 5 bar 5 bar 3 0 3 bar 6 bar 4 0 4...

Страница 12: ...1 3 bar 8 bar 4M1 1 4 bar 10 bar Preferred types Features marked with a symbol at the end of the line are preferred fea tures If you select a preferred feature for each placeholder the device is spec...

Страница 13: ...allation and commissioning Tools and equipment Have the following tools and equipment ready for commissioning Open ended spanner spanner width 27 Screwdriver Make sure that the tools and equipment are...

Страница 14: ...14 23 Instruction Manual VD61 Dimensions A B C D E Side view A Cable gland M16 cable 5 10 mm B Terminal for cable up to 1 5 mm2 C 15 mm D G1 4 female thread E 146 mm B A C Top view A 40 5 mm B 20 mm...

Страница 15: ...commissioning 5 Instruction Manual VD61 15 23 E A B C D F E A B C D F Adapter with G male thread A 32 mm B 5 mm C 6 mm D G1 2 E WAF22 F Material 1 4435 Attenuator with G male thread A 32 mm B 5 mm C...

Страница 16: ...e instructions to install the pressure transmitter A Screw the pressure transmitter on the mounting surface Therefore two boreholes are located in the transmitter housing see next fig Pos F Therefore...

Страница 17: ...use the nut of the pressure transmitter see previ ous fig and not the transmitter housing When screwing do not cross the threads If you use an attenuator or an adapter screw it between the pressure tr...

Страница 18: ...itude Make sure that no moisture enters the cable end X1 X1 VD61 Connection diagram Follow the instructions to connect the cable to the pressure transmit ter A Loosen the two screws see next fig Pos A...

Страница 19: ...nstalled correctly moisture can enter the transmitter housing This may lead to incorrect measurement signal loss or may even damage the transmitter F Screw the covering onto the housing by using both...

Страница 20: ...voltage and the pressure supply Clean the instrument with a moist cloth CAUTION Do not touch the measuring material if used with media that may harm people Otherwise serious injuries can be the result...

Страница 21: ...turn delivery in the Section General information 4 Disposal of defective sensors Electric devices must not be disposed together with normal waste Dis pose the transmitters in accordance with local req...

Страница 22: ...rload caused by overpressure Replace instrument Signal span varies EMC interference sourc es in the environment for example frequency converter Shield instrument cable shield remove source of interfer...

Страница 23: ...Germany Phone 49 381 519944 0 Fax 49 381 519944 4 Email info noris automation de Web www noris group com NORIS Benelux B V Nieuwland Parc 10L 2952DA Alblasserdam Netherlands Phone 31 78 890 7550 Fax...

Отзывы: