NORIS VD61 Скачать руководство пользователя страница 11

NORIS Automation GmbH

Technical data | 4

Instruction Manual VD61

11 / 23

Mechanical properties 

Material 

Parts in contact with measured medium: < 10 

bar CrNi steel 303 and CrNi steel 316L; > 10 

bar CrNi steel 316L and 13-8 PH (AISI), hous

-

ing: Aluminium, powder-coated (check the 

pressure medium for suitability for medi-

um-contacting parts) 

Weight 

Approx. 560 g 

Other 

Approvals 

DNV 

CE Conformity 

Pressure Equipment Directive 97/23/EC; EMC 

Directive 2004/108/EC EN 61326 Emission 

(Group 1, Class B) and interference immunity 

(industrial environment) 

Measuring range VD61
Code

Measuring range

Overload

0 ... 1 bar 

2 bar 

1,6 

0 ... 1.6 bar 

3.2 bar 

2,5 

0 ... 2.5 bar 

5 bar 

0 ... 3 bar 

6 bar 

0 ... 4 bar 

8 bar  

0 ... 5 bar 

10 bar 

0 ... 6 bar 

12 bar 

10 

0 ... 10 bar 

20 bar 

15 

0 ... 15 bar 

30 bar 

16 

0 ... 16 bar  

32 bar 

20 

0 ... 20 bar 

40 bar 

25 

0 ... 25 bar 

50 bar 

30 

0 ... 30 bar 

60 bar 

40 

0 ... 40 bar 

80 bar 

50 

0 ... 50 bar 

100 bar 

60 

0 ... 60 bar 

120 bar 

100 

0 ... 100 bar 

200 bar 

120 

0 ... 120 bar 

240 bar 

150 

0 ... 150 bar 

 300 bar 

160 

0 ... 160 bar 

320 bar 

180 

0 ... 180 bar 

360 bar 

250 

0 ... 250 bar 

 500 bar 

300 

0 ... 300 bar 

600 bar 

400 

0 ... 400 bar 

800 bar 

600 

0 ... 600 bar 

1200 bar 

150P

0 ... 150 psi 

300 psi 

1M1 

-1 ... 1 bar 

4 bar 

Содержание VD61

Страница 1: ...Instruction Manual VD61 NAN KD 0031 EN_V01 01 05 05 2021...

Страница 2: ...Issue NORIS Automation GmbH 2 23 Instruction Manual VD61 Issue Information on issue Document ID NAN KD 0031 EN Issue V01 01 Date April 2021...

Страница 3: ...f safety and warning notes 6 2 4 Scope of delivery 7 2 5 Accessories and spare parts 7 3 Product description 8 3 1 Safety notes 8 3 2 Scope of application 9 3 3 Measuring principle 9 3 4 Type code 9 4...

Страница 4: ...be per formed by qualified and authorised technical personnel in accordance with the relevant documentation especially the safety and warning in formation contained therein Make sure that no excess pa...

Страница 5: ...ts are stored correctly Refer to the correspond ing technical information for further information Disclaimer We review the contents of our technical documentation at regular intervals to ensure it agr...

Страница 6: ...n manual is the installation commissioning operation and maintenance of pressure transmitter series VD61 Further more this instruction manual also contains important troubleshooting infor mation Use o...

Страница 7: ...ssories and spare parts Available accessories Adapter with G male thread Attenuator with G male thread Pos Description Drawing no Order no 01 Adapter with G male thread 59 201 522004 02 Attenuator K6...

Страница 8: ...tter is only used within the overload threshold limit all the time Observe the ambient and working conditions outlined in Tech nical data Observe the technical data for the use of the pressure transmi...

Страница 9: ...tion and use For further information please read the technical data Measuring principle The pressure prevailing within the application is transformed into a stand ardised electrical signal through the...

Страница 10: ...le thread available see accessories Signal acquisition Standard measuring range See measuring range table Electrical output Output signal and maxi mum permissible load 4 20 mA 2 wire RA UB 8 V 0 02 A...

Страница 11: ...ion Group 1 Class B and interference immunity industrial environment Measuring range VD61 Code Measuring range Overload 1 0 1 bar 2 bar 1 6 0 1 6 bar 3 2 bar 2 5 0 2 5 bar 5 bar 3 0 3 bar 6 bar 4 0 4...

Страница 12: ...1 3 bar 8 bar 4M1 1 4 bar 10 bar Preferred types Features marked with a symbol at the end of the line are preferred fea tures If you select a preferred feature for each placeholder the device is spec...

Страница 13: ...allation and commissioning Tools and equipment Have the following tools and equipment ready for commissioning Open ended spanner spanner width 27 Screwdriver Make sure that the tools and equipment are...

Страница 14: ...14 23 Instruction Manual VD61 Dimensions A B C D E Side view A Cable gland M16 cable 5 10 mm B Terminal for cable up to 1 5 mm2 C 15 mm D G1 4 female thread E 146 mm B A C Top view A 40 5 mm B 20 mm...

Страница 15: ...commissioning 5 Instruction Manual VD61 15 23 E A B C D F E A B C D F Adapter with G male thread A 32 mm B 5 mm C 6 mm D G1 2 E WAF22 F Material 1 4435 Attenuator with G male thread A 32 mm B 5 mm C...

Страница 16: ...e instructions to install the pressure transmitter A Screw the pressure transmitter on the mounting surface Therefore two boreholes are located in the transmitter housing see next fig Pos F Therefore...

Страница 17: ...use the nut of the pressure transmitter see previ ous fig and not the transmitter housing When screwing do not cross the threads If you use an attenuator or an adapter screw it between the pressure tr...

Страница 18: ...itude Make sure that no moisture enters the cable end X1 X1 VD61 Connection diagram Follow the instructions to connect the cable to the pressure transmit ter A Loosen the two screws see next fig Pos A...

Страница 19: ...nstalled correctly moisture can enter the transmitter housing This may lead to incorrect measurement signal loss or may even damage the transmitter F Screw the covering onto the housing by using both...

Страница 20: ...voltage and the pressure supply Clean the instrument with a moist cloth CAUTION Do not touch the measuring material if used with media that may harm people Otherwise serious injuries can be the result...

Страница 21: ...turn delivery in the Section General information 4 Disposal of defective sensors Electric devices must not be disposed together with normal waste Dis pose the transmitters in accordance with local req...

Страница 22: ...rload caused by overpressure Replace instrument Signal span varies EMC interference sourc es in the environment for example frequency converter Shield instrument cable shield remove source of interfer...

Страница 23: ...Germany Phone 49 381 519944 0 Fax 49 381 519944 4 Email info noris automation de Web www noris group com NORIS Benelux B V Nieuwland Parc 10L 2952DA Alblasserdam Netherlands Phone 31 78 890 7550 Fax...

Отзывы: