IMPORTANT SAFETY INFORMATION

INSTALLER: Please read all instructions before servicing 
this equipment. Pay attention to all safety warnings and 
any other special notes highlighted in the manual. Safety 
markings are used frequently throughout this manual to 
designate a degree or level of seriousness and should not 
be ignored.

 

WARNING indicates a potentially hazardous 

situation that if not avoided, could result in personal injury 
or death.

 

CAUTION indicates a potentially hazardous 

situation that if not avoided, may result in minor or moderate 
injury or property damage.

 WARNING:

ELECTRICAL SHOCK, FIRE OR 

EXPLOSION HAZARD

Failure to follow safety warnings exactly could 
result in serious injury or property damage.

Improper servicing could result in dangerous 
operation, serious injury, death or property 
damage.

•  Before  servicing,  disconnect  all  electrical 

power to the indoor blower.

•  When servicing controls, label all wires prior 

to disconnecting. Reconnect wires correctly.

•  Verify proper operation after servicing.

 WARNING:

This split system heat pumps is shipped charged 
with R410A refrigerant and ready for installation. 
If repairs make it necessary for evacuation and 
charging, it should only be attempted by qualified 
trained personnel thoroughly familiar with this 
equipment. Under no circumstances should 
the owner attempt to install and/or service this 
equipment. Failure to comply with this warning 
could result in property damage, personal injury, 
or death.

 CAUTION:

This unit uses R-410A refrigerant. DO NOT use 
any other refrigerant in this unit. Use of another 
refrigerant will damage the unit.

 WARNING:

Unless noted otherwise in these instructions, only 
factory authorized parts or accessory kits may 
be used with this product. Improper installation, 
service, adjustment, or maintenance may cause 
explosion, fire, electrical shock or other hazardous 
conditions which may result in personal injury 
or property damage.

•  Installation  of  equipment  may  require  brazing 

operations. Installer must comply with safety codes 
and wear appropriate safety equipment (safety glasses, 
work gloves, fire extinguisher, etc.) when performing 
brazing operations.

•  Follow all precautions in the literature, on tags, and 

on labels provided with the equipment. Read and 
thoroughly understand the instructions provided with 
the equipment prior to performing the installation and 
operational checkout of the equipment.

•  Use caution when handling this appliance or removing 

components. Personal injury can occur from sharp 
metal edges present in all sheet metal constructed 
equipment.

 WARNING:

The information listed below and the next page 
must be followed during the installation, service, 
and operation of this furnace. Failure to follow 
safety recommendations could result in possible 
damage to the equipment, serious personal injury 
or death.

•  The  installer  must  comply  with  all  local  codes  and 

regulations which govern the installation of this type 
of equipment. Local codes and regulations take 
precedence over any recommendations contained in 
these instructions. Consult local building codes and the 
National Electrical Code (ANSI CI) for special installation 
requirements.

•  All electrical wiring must be completed in accordance 

with local, state and national codes and regulations 
and with the National Electric Code (ANSI/NFPA 70) 
or in Canada the Canadian Electric Code Part 1 CSA 
C.22.1.

•  This equipment contains liquid and gaseous refrigerant 

under high pressure. DO NOT USE ANY PORTION OF 
THE CHARGE FOR PURGING OR LEAK TESTING.
Installation or servicing should only be performed by 
qualified trained personnel thoroughly familiar with this 
type equipment.

•  Fully annealed, refrigerant grade copper tubing should 

be used when installing the system. Refrigerant suction 
line tubing should be fully insulated.

•  This unit is designed for outdoor installations only and 

should be positioned as described on 

page 3

.

Содержание T4BD-042 Series

Страница 1: ...n how to operate and maintain the equipment for the life of the product Safety should always be the deciding factor when installing this product and using common sense plays an important role as well...

Страница 2: ...orotherhazardous conditions which may result in personal injury or property damage Installation of equipment may require brazing operations Installer must comply with safety codes andwearappropriatesa...

Страница 3: ...iled immediately with the carrier Pleaseconsultyourdealerformaintenanceinformation and availability of maintenance contracts Please read all instructions before installing the unit Locating the Heat P...

Страница 4: ...dryer is provided with the unit and must be installedintheliquidlineofthesystem Iftheinstallation replaces a system with a filter dryer already present in the liquid line the filter dryer must be rep...

Страница 5: ...y andtherestrictororifice whilebeingcarefulnottoscratch either part Carefully remove the restrictor orifice from the valve body See Figure 3 page 4 3 Check the actual size of the new orifice NOTE The...

Страница 6: ...Diagnostics Module Select Models Only The CoreSenseTM Diagnostics Module Figure 5 page 7 is a breakthrough innovation for troubleshooting heatpumpandairconditioningsystemfailures Themodule installs ea...

Страница 7: ...tart Check List Verify the unit is level and has sufficient clearances for unobstructed airflow Verify the outdoor coil and top of the unit are free from obstructions and debris and all equipment acce...

Страница 8: ...2 sec and does not start within 35 sec 10x consecutive Red Flash4 Yellow Off Code5 Yellow Flash 5 Compressor moderate run trip Compressor runs for 15 min to 18 hrs followed by a compressor trip lastin...

Страница 9: ...Data sheet for additional charging information Outdoor units with non AHRI listed indoor coils are not recommended and deviations from rated airflows or non listedcombinationsmayrequiremodificationtot...

Страница 10: ...ange of operation Reference the charts to determine the ideal amount of sub cooling for a given liquid pressure Units charged to other values will not perform at the rated unit efficiency EER or rated...

Страница 11: ...below the curve T4BD 048KA Charging Chart Cooling Figure 7 Charging Chart for 4 Ton Units TXV Matches 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 75 80 85 90 95...

Страница 12: ...ring wet bulb temperatures are lower than design 1 All pressures are listed in psig and all temperatures in F 2 Discharge temperatures greater than charted values indicate an undercharged system 3 Dis...

Страница 13: ...LIQ PRESS DIS TEMP LIQ PRESS DIS TEMP 121 244 135 123 245 135 267 141 125 246 135 268 141 290 147 127 247 136 269 142 291 147 313 154 129 248 136 270 142 292 148 314 154 336 160 131 271 142 293 148 31...

Страница 14: ...the liquid line temperature on the inlet and outlet of the filter dryers If it is the factory dryer and in good condition there should be no temperature difference If the temperature difference is lar...

Страница 15: ...0 221 232 105 45 239 250 112 60 257 268 120 75 275 286 127 90 288 299 136 105 314 325 146 121 339 350 155 31 228 239 103 46 245 256 110 61 261 272 118 76 278 289 125 91 295 306 133 106 321 332 141 122...

Страница 16: ...ot suitable on systems that exceed 150 volts to ground 4 For replacement wires use conductors suitable for 105 C 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 4...

Страница 17: ...0 volts to ground 4 For replacement wires use conductors suitable for 105 C 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace air h...

Страница 18: ...ts to ground 4 For replacement wires use conductors suitable for 105 C 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace air handle...

Страница 19: ...19...

Страница 20: ...NO INSTALLER NAME CITY________________________ STATE_________________ Has the owner s information been reviewed with the customer YES NO Has the Literature Package been left with the unit YES NO 7096...

Отзывы: