TABLE A-1: BECKETT OIL BURNER SET-UP
BECKETT AFG SERIES OIL BURNERS
FURNACE
MODEL
OUTPUT
BTU/Hr.
BURNER
MODEL
NOZZLE
(Delavan)
PUMP
PRESSURE
FLOW
RATE
HEAD
STATIC
PLATE
58,100
1, 2
AF76BO
0.50 / 70° W
100 PSIG
0.50 GPH
F0
3-3/8 in.
73,700
2
AF76BN
0.65 / 70° W
100 PSIG
0.65 GPH
F3
3-3/8 in.
O4HD-091A
78,900
2
AF76BN
0.70 / 70° W
100 PSIG
0.70 GPH
F3
3-3/8 in.
87,700
2
AF76BZHS
0.75 / 70° W
100 PSIG
0.75 GPH
F4
3-3/8 in.
98,800
AF76BZHS
0.85 / 70° W
100 PSIG
0.85 GPH
F4
3-3/8 in.
O4HD-140A
113,400
AF76BZHS
1.00 / 70° W
100 PSIG
1.00 GPH
F4
3-3/8 in.
1
F0 Head required for proper combustion.
2
Low Firing Rate Baffle required, Beckett Part No. 3708
In the United States, the R. W. Beckett “AFG” Burner may be equipped with Beckett’s “Inlet Air Shut-Off”, Beckett Part No. AF/A 5861, to increase efficiency. It reduces the
amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles.
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.
TABLE A-2: DIRECT DRIVE BLOWER SET-UP
BLOWER SET-UP
COOLING CAPACITY
0.20 in. w.c.
0.50 in. w.c.
FURNACE
OUTPUT
BTU/Hr.
BLOWER
MOTOR
HP
Dip
Switch/Speed
Setting
Dip
Switch/Speed
Setting
Htg. CFM
Range
1
Tons
2
MOTOR
HP
Clg. CFM
Range
58,100 Low
Low
668-1069
73,700 Medium-Low
Medium-Low
841-1346
O4HD-091A-12-
FA
78,900
10-10DD ½
Medium-High Medium-High 910-1456
3 ½
1047-1267
87,700 Low
Low
943-1458
98,800 Low
Medium-Low
1084-1676
O4HD-140A-16-
FA
113,400
11-10DD ¾
Low Medium-Low
1279-1977
5 ¾
1499-1879
58,100 0-0-0
0-0-0
900
73,700 1-0-1
1-0-1
1050
O4HD-091A-V-F
78,900
11 10DD
¾
1-0-0 1-0-0 1200
3 ¾
312-1531
87,700 1-0-0
1-0-0
1200
98,800 0-1-1
0-1-1
1350
O4HD-140A-V-F
113,400
11 10DD
¾
0-1-0 0-1-0 1500
5 ¾
312-1844
(1)
Heating Range values based on temperature rise. Upper values may exceed measured airflow values in Table A-3.
(2)
Nominal values only.