Way to enter menu : * (press for more than 2 seconds), (Admin password) #

Menu Parameter or operation step

Function

Default value

20

0000#

Delete all users

21

Press fingerprint 1 time

Delete user by fingerprint

22

(ID) #, (ID) #,…

Delete user by ID number

40

0, #

Set Alarm time to 0, means no
alarm

0

(1-99)#

Set the alarm time to 1-99
minutes

41

0#

Disable Anti-dismantle alarm

0

1#

Enable Anti-dismantle alarm

50

0#

Indicator light is always off

1

1#

Red indicator light is always on

2#

Green indicator light is always
on

51

1,1,…,#

Decrease the brightness of the
normally bright red indicator

18

2,2,…,#

Increase the brightness of the
normally bright red indicator

54

0#

Disable the buzzer

1

1#

Enable the buzzer

55

1,1,…,#

Decrease the keypad tone

12

2,2,…,#

Increase the keypad tone

60

(0-255)#

Set facility code

0

61

0#

D0 & D1 output wiegand format.

0

1#

D0 output RS232-TTL-HEX
format.

2#

D0 output RS232-TTL-ASCII-8
format.

3#

D0 output RS232-TTL-ASCII-10
format.

62

(26-66)#

The wiegand output format for
reading card can be set from
26-66 bits.

26

63

0#

Wiegand output without parity
check.

1

1#

wiegand output with parity
check(EO format).

Fingerprint Standalone

Access Control User Manual

Содержание Pro-P2

Страница 1: ...Pro P2 Fingerprint Standalone Access Control User Manual...

Страница 2: ...card or fingerprint 10 4 1 4 Set Machine Mode 10 4 1 5 Limit types of reading card 10 4 1 6 Restore to default settings 11 4 1 7 Add User 11 4 1 7 1 Automatically generates ID numbers to add user car...

Страница 3: ...ngerprint operation 16 4 2 7 Normal open card or fingerprint operation 16 4 3 Users operation 17 4 3 1 Get user card or enter fingerprint 17 4 3 2 User open door 17 4 4 Other operation 17 4 4 1 Cancel...

Страница 4: ...rd and 13 56Mhz Mifare card at the same time ISO14443A Low power consumption sensor optical fingerprint to open the door Infrared remote keyboard operation Can be setted as Reader mode Single door mod...

Страница 5: ...put format Wiegand 26 66 bit HID automatic User capacity 20000 Admin card capacity 21 User fingerprint capacity 219 Admin fingerprint capacity of 21 Electric lock signal relay contact current 1A Alarm...

Страница 6: ...Note 1 Color box 1 2 Standalone access control 1 3 User manual 1 4 Punch stickers 1 5 Decorative sheet 1 6 Expansion rubber plug 6mm 30 mm 4 White 7 Self tapping screw KA3mm 25 mm 4 Galvanized 2 2Inst...

Страница 7: ...er checking all is correct shortly power on to test whether the indicator light is normal and the buzzer beeps otherwise immediately cut off the power supply recheck whether the wiring is correct and...

Страница 8: ...789 these12 buttons means continue similar operation as indicated from previous operations is not an actual operation it s just punctuation means the serials of digital numbers which will be type into...

Страница 9: ...ps When admin card exit A long beep Press digit key A short beep Press key A long beep Card fingerprint Mode after reading the card Red slow flash Multi user open door unfinished Red slow flash Enter...

Страница 10: ...eat the operation till the last user card Note the controller can read multi cards or fingerprints continuously each fingerprint press twice When you hear a long beep and indicator light turn to green...

Страница 11: ...Password 00 New Admin Password Repeat Admin Password Note New Admin Password must be 6 digits 4 1 2 Set admin card Fingerprint 01 0 read card or press fingerprint twice Set 1 3 Set cards or fingerprin...

Страница 12: ...03 9 Set to Demo mode Note Factory default mode is Single door mode 4 1 5 Limit types of reading card 04 0 cannot read any card 04 1 can read EM card only 04 2 can read HID card only 04 3 can read IC...

Страница 13: ...ID read card or press fingerprint twice Specify ID number and input 8 digit card number to add user 11 ID 8 8 digit format card number ID 8 8 digit format card number Specify ID number and input 10 di...

Страница 14: ...if card and fingerprint are the same ID as one user 4 1 10 Set the number of doors opened by multi user 31 2 10 read 2 10 cards or fingerprints in order to open the door the door opening mode must be...

Страница 15: ...Controller s special power supply should set to minimum time to ensure the actual Unlock time match with user s settings 4 1 14 Set notification to close door 35 0 99 the default value is 10 set the t...

Страница 16: ...fault setting the controller will alarm or lock up for some time 4 1 18 Set LED indicator light mode 50 0 standby LED indicator light is off 50 1 default value standby LED indicator light always red 5...

Страница 17: ...e is 0 set facility code Note The facility code will be used when fingerprint ID output See the following sections for specific use 4 1 22 2 Set D0 D1 output format 61 0 D0 D1 output wiegand format 61...

Страница 18: ...ng fingerprint 63 0 wiegand output without parity check 63 1 default value wiegand output with parity check EO format Note EO format is standard wiegand format Even check data add in front and Odd che...

Страница 19: ...riety of way to open the door or restrict the user to open the door the Super open card or fingerprint can open the door 4 2 5 Anti duress card or fingerprint operation Read Anti duress card or finger...

Страница 20: ...s red and keep In card PIN open mode or multi card open door mode the interval time of reading card or inputting PIN cannot be more than 5 seconds 4 4 Other operations 4 4 1 Cancel alarming Read admin...

Страница 21: ...ED and BZ are as follows LED Green LED control wire LED turns to green when low level BZ Buzzer control wire Buzzer keep sounds when low level 4 5 2 Operation characteristics in Single door mode The d...

Страница 22: ...00000 Delete 21 Admin cards or fingerprint 0 Delete 3 Set cards or fingerprint 1 Delete 3 Adding cards or fingerprint 2 Delete 3 Deleting cards or fingerprint 03 0 Reader mode 1 1 Single door mode 3 I...

Страница 23: ...icator light is always on 51 1 1 Decrease the brightness of the normally bright red indicator 18 2 2 Increase the brightness of the normally bright red indicator 54 0 Disable the buzzer 1 1 Enable the...

Страница 24: ...3 Super open cards or fingerprint 4 read card or press fingerprint twice Set 1 3 Anti duress cards or fingerprint 5 read card or press fingerprint twice Set 1 3 Authorization cards or fingerprint 6 r...

Страница 25: ...ID read card or press fingerprint 2 times Specify ID number and read card or fingerprint to add user ID 8 8 digit format card number ID 8 8 digit format card number Specify ID number and input 8 digi...

Страница 26: ...use 34 0 Set Open time to 50mS 2 1 999 Set Open time from 1 to 999S 35 0 99 After opening the door delay 0 99 seconds to start the tone 10 36 0 99 Set the closing prompt tone for 0 99 seconds 10 40 0...

Страница 27: ...er mode 1 1 Single door mode 3 Interlock mode 9 Demo mode 09 0000 Restore default settings operating mode admin password and user information unchanged 32 0 Set lock to Delay mode 0 1 Set lock to Swit...

Страница 28: ...ifferent 7 Common troubleshooting Fault phenomenon Possible causes Troubleshooting Indicator light is not working properly 1 The power line is too thin Replace thicker qualified wire 2 Wrong connectio...

Страница 29: ...ed lock or parallel connect a 470uF 25V electrolytic capacitor at the two ends of the lock Can t recognize fingerprint 1 Dryness and broken of finger skin Moisture the finger or change another finger...

Отзывы: