(or fingerprint) in the first mode, it can switch to Normal-open mode and normal status quickly.
The operation of Normal-open card(or fingerprint), see relevant chapter of admin cards(or
fingerprint) operation.
4.1.12 Set Limits User Mode
33, 0#, disable users to use.
33, 1#, default value, enable users to use.
Notes: A better way to implement the limits of user mode is operation by
Authorization-card(or fingerprint), it can switch to disable and enable users to operate quickly.
The operation of Authorization-card(or fingerprint), see relevant chapter of admin cards(or
fingerprint) operation.
4.1.13 Set Open-time
34, 0#, set Open-time to 50mS, apply to electrically controlled lock for external
instantaneous large current
34, (1-999) #, the default value is 2, set Open-time from 1 to 999s.
Note: Unlock-time of Access Controller’s special power supply should set to minimum time
to ensure the actual Unlock-time match with user’s settings.
4.1.14 Set notification to close door
35, (0-99) #, the default value is 10, set the time to notify when user don’t close the door
after open it beyond the setting time. the buzzer begin to beep for notification.
36, (0-99) #, the default value is 10, set the time for beeping.
Note: If you don’t need notification, can set the time for beeping to 0.
4.1.15 Set Alarm-time
40, 0#, default value, if set Alarm-time to 0 means no alarm.
40, (0-99) #, Alarm-time is set from 1 to 99 minutes.
4.1.16 Set Anti-dismantle alarm function
41, 0#, default value, disable Anti-dismantle alarm function.
41, 1#, enable Anti-dismantle alarm function.
Note: When the machine is illegally dismantled, it alarms and an alarm signal will be send
out at the same time. The alarm can be canceled by inputting Admin Password, read admin
card(or fingerprint) or user card(or fingerprint).
Fingerprint Standalone
Access Control User Manual