1
1
Applicators PatternCoat
19
P/N 7135308_08
E
2014 Nordson Corporation
PatternCoat
Regular Maintenance
The maintenance intervals are general guidelines based on experience.
Depending on operating environment, production conditions and hours of
operation, other maintenance intervals may prove necessary.
Unit part
Activity
Interval
Refer to
Applicator
Purge with cleaning agent
When dirty or when
changing adhesive
-
Control module
Check detection hole
Weekly
Page
19
Filter
Replace filter cartridge
As needed
Page
19
Nozzle
Clean
As needed
Page
Adjusting device
Application width
Lubricate
As needed
Page
Check detection hole
If material escapes from the detection hole (1), the interior O‐rings have worn
and the control module must be replaced.
Replacing Filter Cartridge
1. Relieve system pressure.
2. Unscrew the filter cartridge (1).
3. Insert the new filter cartridge and tighten with 3 - 4 Nm (2 - 3 ft‐lbs).
Filter cartridges are available in packs of two or five. Refer to page
Spare