Maintenance
5-1
Part 7135457- E
E
2017 Nordson Corporation
Section 5
Maintenance
WARNING:
Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
WARNING:
Breathing in certain airborne dusts (including finishing
powders) may be hazardous to health. Ask the powder manufacturer for a
Material Safety Data Sheet (MSDS) for information. Use appropriate
respiratory protection.
Daily Maintenance
NOTE:
For daily maintenance of the Afterfilter, Sieve, Powder Port and
Feed Center Lite refer to the relevant technical manuals.
S
Once per eight hour shift, disassemble all powder components, clean
each item removing any excess powder, wipe with a lint free cloth and
then reassemble.
S
Inspect seals for damage and replace as necessary
S
Check vent hoses for blockages, clean and refit.
S
Check all external cables and hoses for damage, replace or repair as
necessary.
S
Visually check the complete system for leaks, rectify as necessary.
S
Check the operation of the powder transfer system.
S
Every four hours, with the fan in operation, clean the booth interior,
blowing the powder into the cyclone inlet of the booth.
S
Every four hours check the collector bin levels, if the bin is above half
full, empty it.
S
Every four hours or less check the feeder hopper or powder box for
powder level.
S
Every four hours check the powder pump and gun, clean according to
the product manual.