Pinch Valve Assembly
7
Part 768670A
.
2005 Nordson Corporation
Installation
WARNING:
Allow only qualified personnel to perform the following tasks.
Observe and follow the safety instructions in this document and all other
related documentation.
WARNING:
Risk of electrical shock. Disconnect and lock out input power to
equipment before servicing. Failure to observe this warning may result in
personal injury or death
Transport
Transport the unit so as to avoid damage. Use suitable packaging materials
and sturdy cartons. See Specifications section for dimensions and weights.
Protect the unit from exposure to humidity, dust and vibrations.
Unpacking
Carefully unpack the unit avoiding damage. Check for damage caused
during transport. Save packing materials for possible later use, otherwise
recycle or dispose of properly according to local regulations.
Removing
Switch off the main electrical and pneumatic supplies.
Storage
Pack the unit in suitable packing materials and sturdy cartons. Protect from
humidity, dust and large temperature fluctuations. Add a layer of grease to
all moving parts to prevent rust.
Disposal
Dispose of properly according to local regulations.
Electrical
:
Ensure that the earth wire is connected to a suitable earthing point.
:
Connect suitable power supply (220v) to optional electric vibrator.
Pneumatic
:
Ensure that air supply is at 6 Bar pressure.
:
Connect pneumatic hoses to pinch valves.