PICO
Toµch
Series Controllers
61
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Appendix A, Remotely Operating the Controller
(continued)
Valve (Driver)
Command
Description
Command Format
Sample, with Output
After [Enter]
drv1
Sets the valve mode
(MODE)
x = 1–5
Where
x
equals:
1drv1
Sets MODE to Timed
2drv1
Sets MODE to External / Purge
3drv1
Sets MODE to Continuous
5drv1
Reads the current mode
1drv1
[Enter]
Driver 1: TIME
2drv1
[Enter]
Driver 1: PURG
3drv1
[Enter]
Driver 1: CONT
5drv1
[Enter]
Driver 1: CONT
dcn1
Sets the valve dispense
count (COUNT)
xxxxxdcn1
Where
x
equals: >
00001–65535
counts
(DCNT)
00001dcn1
[Enter]
Dispense Count (DCNT) = 00001
ont1
Sets the valve ON time
(PULSE)
xxxx.xxont1
Where
xxxx.xx
= ON time in ms
NOTE:
Time is entered as an ON / OFF
time where ON = PULSE and CYCLE =
ON + OFF. ON and OFF times should be
adjusted together to preserve the CYCLE
time setting.
0001.45ont1
[Enter]
Time Set To = 0001.45 ms
oft1
Sets the valve OFF time
(CYCLE)
(Where OFF time + ON
Time = CYCLE)
xxxx.xxoft1
Where
xxxx.xx
= OFF time in ms
NOTE:
Time is entered as an ON / OFF
time where ON = PULSE and CYCLE =
ON + OFF. ON and OFF times should be
adjusted together to preserve the CYCLE
time setting.
0005.00oft1
[Enter]
Time Set To = 0005.00 ms
rdr1
Returns the valve status
rdr1
rdr1
[Enter]
Power: OFF
MODE : TIME
PULSE: 0002.00ms
CYCLE: 0004.00ms
COUNT: 00001
Profile Rise.: 6
Profile Fall.: 6
Stroke.......: 0070
Up Ramp Time.: 000.500ms
Dwn Ramp Time: 000.250ms
Close Voltage: 090
Numb Shots...: 0000398174
Power Mode: ON at boot up
Continued on next page