PICO
Toµch
Series Controllers
47
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Part Numbers
Standard
Toµch
Controller
NOTE:
Refer to “
XP Controller Part Number” on page 75 for the
Toµch
XP
controller part number.
Part #
Description
7361217
PICO
Toµch
controller
Routine Shutdown
1. Stop the process.
2. De-pressurize the system.
WARNING
Risk of burns. Wear heat-protective gloves when working with a heated valve.
3. If the valve is heated, switch OFF heater control.
4. Refer to the valve manual to perform any of the following procedures as appropriate for the fluid:
• Removing the fluid body assembly.
• Purging the valve with the process fluid.
• Purging the valve with cleaning fluid.
• Cleaning the valve fluid paths.
Operation (continued)
Valve Extension Cables (Standard
Toµch
Controller)
NOTE:
The
Toµch
XP controller requires different extension cables from the standard
Toµch
controller. Refer to
XP Valve Extension Cables” on page 75 for the
Toµch
XP controller extension cables.
Risk of equipment damage. The standard
Toµch
controller does not accept extension cables designed for the
Toµch
XP controller.
CAUTION
Do not exceed the maximum extension cable length of 9 m (30 ft). Doing so will adversely affect communication
between the valve and the controller.
CAUTION
Part #
Description
Comment
7362085
0.6 m (2.0 ft) valve extension cable set
Includes one each for power and
communication
7361298
2 m (6.6 ft) valve extension cable set
7361299
6 m (19.7 ft) valve extension cable set
7361300
9 m (29.5 ft) valve extension cable set