Operation
Follow these recommended procedures for daily / routine
startup and shutdown to obtain the best performance from
your system.
CAUTION
The
Pµlse
valve is normally open and power must be
applied to close it. In the case of damage to the piezo
actuator or the
Toµch
controller, the valve may transition
from a CLOSED to an OPEN condition, which can cause
fluid release. Nordson EFD recommends continually
monitoring the status signal of the
Toµch
controller and
immediately and automatically de-pressurizing the system if
the signal indicates an error.
Routine Startup
1. Switch the
Toµch
controller power ON.
2. If the process requires a heated valve, press the
HEATERS icon and then press ON to switch the
HEATERS mode to On.
NOTE:
Upon reboot, the controller remembers the last
selected HEATERS mode.
1
Switching on heater control