PROFIBUS Communicator Setup
Applicability of this Section
This section provides only the additional information required to set up a PICO controller with the PROFIBUS
communicator expansion. Refer to “Setup” on page 16 for all other setup information.
Parameterization of the PICO Controller Via the PROFIBUS
Communicator
Organization of the Bus System/Parameterization
• The default baud rate on the CAN bus between the PROFIBUS communicator and the PICO controller is
125 kBit/s.
• The default setting for the PICO controller CAN address is 63. The System Data/CAN menu option in the PICO
controller displays this. Changing the value is NOT possible. The Nordson EFD PROFIBUS communicator
communicates exclusively with this CAN address.
• The default setting for the communicator CAN address is 1.
• All parameters that can be changed via TXT/SD card can be modified via the PROFIBUS communicator. An
exception is the code protection defined by the TXT file.
• The PICO controller occupies, respectively, 8 bytes of input data and 8 bytes of output data in the process image
on the PROFIBUS communicator. The parameterization of the PICO controller is sequentially written and read via
the process image.
• The 8 data bytes of the defined protocol are converted 1:1 into the cyclic process image of the PROFIBUS
communicator.
• Dispensing processes can also be started and stopped via the process image. To start, all 99 lines can be
addressed. In the process, the bus runtimes must be considered.
• The process image cannot be used to query the status and error messages that were interchanged between the
PICO controller and the PICO
Toµch
controller.
PICO Controller 2+2-XCH-V3
64
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.