Inspect Kit Components
After unpacking the equipment, check that the scope of delivery is complete and that your operating conditions
comply with the information on the rating plate.
Refer to “Unpack and Inspect” on page 12 for the components shipped with all PICO controllers. The PICO
controller V3 kit includes the following additional components:
• One Nordson EFD PROFIBUS communicator (P/N 7029246)
• One SD card containing the S7 PROFIBUS project and GSD file
• One 24 V, 2 m power supply cable for the PROFIBUS communicator (P/N 7830499)
• One 0.5-m terminated CAN cable for connecting the PICO controller to the PROFIBUS communicator (P/N 7029237)
PROFIBUS Communicator Installation
Make the System Connections
Prior to conducting work on the system, ensure that running processes will not be interrupted. If necessary, turn off
the system. Only qualified and trained personnel may perform work on the system.
CAUTION
1. Turn off devices/systems/processes to avoid interrupting running processes.
2. Create the connection between the PLC (e. g., the SIEMENS S7-PLC) and the PROFIBUS communicator.
3. Create the PROFIBUS termination on the first and last plug of the PROFIBUS strand (refer to “Installation
Examples” later in this section as needed.)
4. Create the CAN connection between the PROFIBUS communicator and the PICO controller (cable
P/N 7029237). If using a customer-supplied CAN cable, create the CAN termination. CAN cable P/N 7029237 is
already terminated). Refer to “Connector Pin Assignments and Signal Levels” later in this section for connection
details.
5. If necessary, follow these steps to reset the PROFIBUS communicator address (in this example, the address is
set to 63):
a. Carefully remove the protective cover without touching the circuit board or other components.
b. Turn rotary switch B to 6 and rotary switch A to 3.
NOTE: By default, the PROFIBUS communicator is set to address 22. The S7 project described in the operating
manual and provided with the system on the SD card functions with address 22 for the communicator. The address
cannot be changed during operation. That means that the communicator requires a power OFF/ON reset for each
change so that the change can be applied. Refer to the PICO
Toµch
controller operating manual to connect the
valve(s) to the PICO
Toµch
controller.
6. Create a hardwire connection between the PLC, the PICO controller, and the PICO
Toµch
controller
(Y-connection cable, P/Ns 7028222 and 7012975). Refer to “Connector Pin Assignments and Signal Levels” on
page 13 and to “PROFIBUS Interface D-Subconnector Pins” on page 63 for connection details.
7. Establish the power supplies to the PLC, the PROFIBUS communicator (cable P/N 7830499), the
PICO controller (cable P/N 7027455), and the PICO
Toµch
controller (refer to the PICO
Toµch
controller
operating manual if needed).