![Nordson EFD 2+2-XCH-V3 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/nordson-efd/2-2-xch-v3/2-2-xch-v3_operating-manual_1704535026.webp)
CAN Communication Command Examples (continued)
Dispensing START/STOP Command Examples
1FF 88
00 01 xx
xx
xx xx xx Request: START Ch1; Line 01. LS=0. TAN=0.
5FF 88
00 01 xx
xx
xx xx xx Response with Error Bit 0. No error.
1FF 98
10 xx xx
xx
xx xx xx Request: STOP Ch1; LS=0. TAN=1.
5FF 98
10 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
STORE/ERASE Parameter and KEEP ALIVE Command Examples
1FF 4F
20 xx xx
xx
xx xx xx Request: STORE parameters of RAM in EE memory for Ch1+2+3+4. LS=0.
TAN=2.
5FF 4F
20 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
1FF 6F
30 xx xx
xx
xx xx xx Request: STORE&FLASH parameters of RAM in EE memory for Ch1+2+3+4.
LS=0. TAN=3.
5FF 6F
30 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
1FF 58
40 xx xx
xx
xx xx xx Request: ERASE parameters of RAM for Ch1. LS=0. TAN=4.
5FF 58
40 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
1FF 5C
50 xx xx
xx
xx xx xx Request: ERASE parameters of RAM for Ch1+2. LS=0. TAN=5.
5FF 5C
50 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
1FF 5F
60 xx xx
xx
xx xx xx Request: ERASE parameters of RAM for Ch1+2+3+4. LS=0. TAN=6.
5FF 5F
60 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
1FF 7F
70 xx xx
xx
xx xx xx Request: KEEP ALIVE for Ch1+2+3+4. LS=0. TAN=7.
5FF 7F
70 xx xx
xx
xx xx xx Response with Error Bit 0. No error.
Examples for Responses with Error Bit=1
1FF 28
80 64 01
40
D0 00 00 Request: WRITE Ch1; Line 100. Pulse Time=6.5 (IEE754). Set LS=0 and TAN=8.
5FF 28
81 64 01
xx
xx xx xx Response with Error Bit 1 because Line Number and ValueCode do not match.
1FF 28
90 01 01
00
00 00 16 Request: WRITE Ch1; Line 1. Pulse Time=16 . LS=0. TAN=9.
5FF 28
91 01 01
xx
xx xx xx Response with Error Bit 1 because of wrong value for Pulse Time; the byte type
must be Float (refer to “Value Codes and Admissible Value Ranges” on page 79)
1FF 88
A0 01 xx
xx
xx xx xx Request: START Ch1; Line 1. LS=0 .TAN=10.
5FF 88
A1 01 xx
xx
xx xx xx Response with Error Bit 1 because Ch1 not in “Fieldbus” mode or dispensing still
active.
PICO Controller 2+2-XCH-V3
26
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.