Structure of Data Bytes 0–7 (continued)
Byte 1 = Transaction Number (TAN) + Status Flag
Bit 7
Bit 6
Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Nibble Value
Decimal
Description
TAN
TAN
TAN
TAN
x
x
x
x
0-15
TAN is set by master. PICO controller responds with
same TAN.
TAN
TAN
TAN
TAN
1
x
x
x
8
Busy Flag=1 response from PICO controller in case no
data can be received.
TAN
TAN
TAN
TAN
0
x
x
x
0
Busy Flag=0
TAN
TAN
TAN
TAN
x
1
x
x
4
Reserved for future use
TAN
TAN
TAN
TAN
x
0
x
x
0
Reserved for future use
TAN
TAN
TAN
TAN
x
x
1
x
2
Local Service enable, bit set by master to 1
TAN
TAN
TAN
TAN
x
x
0
x
0
Local Service disable, bit set by master to 0
TAN
TAN
TAN
TAN
x
x
x
1
1
Error Flag = 1. Error response from PICO controller
TAN
TAN
TAN
TAN
x
x
x
0
0
Error Flag = 0. Response from PICO controller. Last
transmission without error.
Byte 2 = Line number for Value/ValueCode
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0 Byte Value
Decimal
Description
0
0
0
0
0
0
0
1
1
Line 1 (for Line Values only)
0
0
0
0
0
0
1
0
2
Line 2 (for Line Values only)
—
—
—
—
—
—
—
—
—
Line xx (for Line Values only
0
1
1
0
0
0
1
1
99
Line 99 (for Line Values only)
0
1
1
0
0
1
0
0
100
Line 100 (for Channel Values only)
0
1
1
0
0
1
0
1
101
Line 101 not used
—
—
—
—
—
—
—
—
—
—
1
1
1
1
1
1
1
1
255
Line 255 not used
Byte 3 = ValueCode
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte Value
Decimal
Naming: Controller Display/TXT file (Type of Value)
0
0
0
0
0
0
0
1
1
Pulse Time/dosing time (Line Value)
0
0
0
0
0
0
1
0
2
-/Pause Time (Line Value)
0
0
0
0
0
0
1
1
3
Cycl.count/number of runs (Line Value)
0
0
0
0
0
1
0
0
4
Activation /IN (Line Value)
0
0
0
0
0
1
0
1
5
Linkage/connected line (Line Value)
0
0
0
0
0
1
1
0
6
Delay/connecting time (Line Value)
0
0
0
0
0
1
1
1
7
Block Count/blocknumber (Line Value)
0
0
0
0
1
0
0
0
8
Dosing Value/dosing value (Line Value)
0
0
0
0
1
0
0
1
9
Ext.Puls/ext.puls (Line Value)
0
0
0
0
1
0
1
0
10
Container/container (Channel Value)
0
0
0
0
1
0
1
1
11
Limit/limit (Channel Value)
0
0
0
0
1
1
0
0
12
-/adjustable range (Channel Value)
0
0
0
0
1
1
0
1
13
Temperature/temperature (Channel Value)
0
0
0
0
1
1
1
0
14
Stop/stop (Channel Value)
0
0
0
0
1
1
1
1
15
-/Delay-time (Channel Value)
0
0
0
1
0
0
0
0
16
Remaining/ (Channel Value)
Continued on next page
PICO Controller 2+2-XCH-V3
23
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.