11. Module reference: Sequencer group
NORD MODULAR G2 V1.1
Page 182
S
S
S
S
T
T
T
TE
E
E
EP
P
P
P
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
NS
S
S
S
Click on the buttons to make the sequencer send a Trig/Gate signal each time it pass-
es the step. Note that the two Step button rows on the Event Sequencer work in par-
allel.
S
S
S
S
T
T
T
TE
E
E
EP
P
P
P
LED
LED
LED
LED
S
S
S
S
The Step LEDs indicate the current step in the sequence.
C
C
C
C
O
O
O
ON
N
N
NT
T
T
TR
R
R
RO
O
O
OL
L
L
L
S
S
S
SIIIIG
G
G
GN
N
N
NA
A
A
AL
L
L
L
A
A
A
AR
R
R
RR
R
R
RO
O
O
OW
W
W
W
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
NS
S
S
S
////
S
S
S
SL
L
L
LIIIID
D
D
DE
E
E
ER
R
R
RS
S
S
S
You set the control signal level of each step by moving the vertical slider or clicking
the arrow buttons that appear below each slider when you move the cursor over it.
Note that when you click-hold to move the slider, the cursor becomes invisible.
Range: +/- 64 units in bipolar mode and 0-64 units in unipolar mode (see the Uni
button description below).
T/G
T/G
T/G
T/G
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
N
Toggle between Trig and Gate mode with these buttons. In the Trig mode, every
step transmits its own logic signal, at a 50% duration cycle. In the Gate mode, two or more ad-
jacent activated steps will mix into a “longer" logic signal.
L
L
L
L
IIIIN
N
N
NK
K
K
K
O
O
O
OU
U
U
UT
T
T
TP
P
P
PU
U
U
UT
T
T
T
This yellow output transmits a high logic signal whenever the sequencer goes beyond the last
step in the sequence. This signal can be used for linking several sequencers in series. See more
about linking at the end of this chapter.
C
C
C
C
L
L
L
LR
R
R
R
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
N
Pressing this button will reset all control values to 0.
R
R
R
R
N
N
N
ND
D
D
D
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
N
This produces a random set of control signal values for each of the 16 steps.
B
B
B
B
IIII
P/U
P/U
P/U
P/U
N
N
N
NIIII
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
N
Selects uni- or bipolar control signals of the output of the sequencer.
T
T
T
T
R
R
R
RIIIIG
G
G
G
/G
/G
/G
/G
A
A
A
AT
T
T
TE
E
E
E
S
S
S
SIIIIG
G
G
GN
N
N
NA
A
A
AL
L
L
L
O
O
O
OU
U
U
UT
T
T
TP
P
P
PU
U
U
UT
T
T
T
((((
S
S
S
S
))))
Signal:
Logic
C
C
C
C
O
O
O
ON
N
N
NT
T
T
TR
R
R
RO
O
O
OL
L
L
L
S
S
S
SIIIIG
G
G
GN
N
N
NA
A
A
AL
L
L
L
O
O
O
OU
U
U
UT
T
T
TP
P
P
PU
U
U
UT
T
T
T
Signal:
Unipolar
or
Bipolar
.
S
S
S
S
E
E
E
EQ
Q
Q
Q
E
E
E
E
V
V
V
VE
E
E
EN
N
N
NT
T
T
T
This basic step sequencer features two
parallel rows of 16 steps. Each step can
send two separate logic pulses on the two
separate outputs. Activate a step by
clicking on one or more of the 32 avail-
able trigger buttons. See also
.