NORD MODULAR G2 V1.1
11. Module reference: Sequencer group
Page 181
S
S
S
S
E
E
E
EQ
Q
Q
QU
U
U
UE
E
E
EN
N
N
NC
C
C
CE
E
E
ER
R
R
R
G
G
G
GR
R
R
RO
O
O
OU
U
U
UP
P
P
P
The sequencer modules can perform different functions during the course of a specified time. The se-
quencer modules in the Nord Modular G2 system has (up to) 16 steps each. They can easily be linked
together in series to provide longer sequences and they can be clocked by various clock sources, originat-
ing from other modules or from the Master/MIDI clock. The sequencer modules can be synchronized to
each other in a number of ways. Read more about some of the possible combinations with the sequencer
modules at the end of this chapter.
C
C
C
C
O
O
O
OM
M
M
MM
M
M
MO
O
O
ON
N
N
N
S
S
S
S
E
E
E
EQ
Q
Q
QU
U
U
UE
E
E
EN
N
N
NC
C
C
CE
E
E
ER
R
R
R
P
P
P
PA
A
A
AR
R
R
RA
A
A
AM
M
M
ME
E
E
ET
T
T
TE
E
E
ER
R
R
RS
S
S
S
C
C
C
C
L
L
L
LK
K
K
K
IIIIN
N
N
NP
P
P
PU
U
U
UT
T
T
T
This is the
Dynamic Control/Audio
signal input for incoming clock pulses. An incoming signal
which goes from 0 units or below to anything above 0 units will advance the sequencer one step.
R
R
R
R
S
S
S
ST
T
T
T
IIIIN
N
N
NP
P
P
PU
U
U
UT
T
T
T
This is a yellow input where a high logic signal will restart the sequencer (force it to step 1
again). The restart isn’t performed until the next the clock pulse is received at the Clk input.
This guarantees perfect timing.
L
L
L
L
O
O
O
OO
O
O
OP
P
P
P
IIIIN
N
N
NP
P
P
PU
U
U
UT
T
T
T
This is a yellow input where a high logic signal will restart the sequencer (force it to step 1
again). The Loop input can be used to patch a Link signal from the last sequencer module in a
serial connection (see below).
P
P
P
P
A
A
A
AR
R
R
RK
K
K
K
IIIIN
N
N
NP
P
P
PU
U
U
UT
T
T
T
This is a yellow input where a high logic signal/pulse will park, i.e. stop the sequencer.
The sequencer will restart at step 1 when a high logic signal is present on the Rst or Loop
input (see above).
G
G
G
G
A
A
A
AT
T
T
TE
E
E
E
IIIIN
N
N
NP
P
P
PU
U
U
UT
T
T
T
((((
S
S
S
S
))))
These inputs can be used to patch the Trig/Gate output (see below) signals from the pre-
vious sequencer module when you use several sequencers in series. The input signals will
simply be mixed or throughput to the module’s Trig/Gate outputs (see below).
C
C
C
C
O
O
O
ON
N
N
NT
T
T
TR
R
R
RO
O
O
OL
L
L
L
S
S
S
SIIIIG
G
G
GN
N
N
NA
A
A
AL
L
L
L
IIIIN
N
N
NP
P
P
PU
U
U
UT
T
T
T
These inputs can be used to patch the Control signal output (see below) signals from the
previous sequencer module when you use several sequencers in series. The input signals
will simply be mixed or throughput to the module’s Control signal outputs (see below).
L
L
L
L
O
O
O
OO
O
O
OP
P
P
P
/1-C
/1-C
/1-C
/1-C
Y
Y
Y
YC
C
C
CL
L
L
LE
E
E
E
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
N
Click to switch between Loop mode and 1-Cycle mode. In Loop mode, the sequencer restarts
at step 1 immediately after the last step in the sequence. In 1-Cycle mode, the sequencer only
runs from step 1 to the last step and then stops.
S
S
S
S
T
T
T
TE
E
E
EP
P
P
PS
S
S
S
A
A
A
AR
R
R
RR
R
R
RO
O
O
OW
W
W
W
B
B
B
BU
U
U
UT
T
T
TT
T
T
TO
O
O
ON
N
N
NS
S
S
S
Set the last step in the sequence. The sequencer will return to step 1 if Loop mode is
on, or stop if Loop mode is off. Set the last step with the arrow buttons. Range: 1 to
16 steps.