www.norcold.com
Test L: Refrigerator Defrosts
The refrigerator cools to thermostat setting but does not restart until
thawing begins.
If the refrigerator exhibits this symptom, contact Norcold Customer
Service (1-800-543-1219) or the OEM Cutomer Relations for the
appropriate replacement parts.
Remove refrigerator from enclosure,
but keep a power supply connected.
Did the unit
maintain
temperature?
Replace the thermostat and
the DC power cord.
YES
Complete the “Diagnostic Pre-Checks.”
Bypass the thermostat wires:
- Red with white tracer
- Red with blue tracer
Allow the unit to run for eight hours.
Replace the cooling unit.
NO
NOR000980A