Series DE/EV0041, Series DE/EV0061, DC0061
www.norcold.com
28
Test O: Short Cycling
Remove refrigerator from enclosure,
but keep a power supply connected.
Did the unit
continue to restart
with brief periods
of operation
(short cycle)?
YES
Complete the “Diagnostic Pre-Checks.”
Bypass the thermostat wires:
- Red with white tracer
- Red with blue tracer
Allow the unit to run for eight hours.
Replace the cooling unit.
NO
Replace the thermostat and
DC power cord.
NOR000982A
The refrigerator cools in brief operational periods followed by re-
start process which drains power source.
If the refrigerator exhibits this symptom, contact Norcold Customer
Service (1-800-543-1219) or the OEM Cutomer Relations for the
appropriate replacement parts.