Norco Eco-Stim NC89481 Скачать руководство пользователя страница 6

11

10

8)  Do not apply stimulation while sleeping.
9)  Do not apply stimulation while driving, operating machinery,  

 

or during any activity when electrical stimulation can put you  

 

at risk of injury. 

10)  Apply stimulation only to normal, intact, clean, healthy skin. 
11)  The long-term effects of electrical stimulation are unknown.  

 

This electrical stimulation device cannot replace drugs.

12) Stimulation should not take place while the user is 

 

  connected to high-frequency surgical equipment, which  

  may cause burn injuries on the skin under the electrodes,  

 

as well as problems with the stimulator.

13) Do not use the stimulator in the vicinity of shortwave or  

  microwave therapy equipment, since this may affect the  

 

output power of the stimulator. 

14)  Never use in the thoracic area. Stimulation electrodes should  

  never be placed anywhere on the front of the thorax  

(marked by ribs and breastbone), and not on the  

two large pectoral muscles. Placing electrodes in  

these areas can increase the risk of ventricular  

fibrillation and lead to cardiac arrest.

15)  Never place electrodes on eyes, head or face. 
16)  Never place electrodes near genitals. 
17)  Never place electrodes on skin that lacks  normal sensation.
18) Keep electrodes separated during treatment. It could result  

  in improper stimulation or skin burns if electrodes are in  

 

contact with each other.

19)  Keep the stimulator out of reach of children.
20)  Consult your doctor if you have any questions.
21)  Discontinue use and do not increase the intensity level if you  

 

feel discomfort during use.

2.2.3         Precautions

1)  TENS is not effective for pain of central origin including  

 headache. 
2)  TENS is not a substitute for pain medications and other pain  

 

management therapies. 

3)  TENS is a symptomatic treatment and, as such, suppresses  

  the sensation of pain that would otherwise serve as a  

 

protective mechanism.

4)  Effectiveness is dependent upon patient selection by a  

 

practitioner qualified in the management of pain. 

5)  Since the effects of stimulating the brain are unknown,  

  stimulation should not be applied across your head, and  

  electrodes should not be placed on opposite sides of  

 

your head.

6)  The safety of electrical stimulation during pregnancy has  

 

not been established.

7)  You may experience skin irritation or hypersensitivity due to  

  the electrical stimulation or electrical conductive medium  

 

(silica gel).

8)  If you have suspected or diagnosed heart disease or  

  epilepsy, you should follow precautions recommended by  

 

your physician. 

9)  Do not use if you have a tendency to bleed internally, e.g.  

 

following an injury or fracture.

10) Consult with your physician prior to using the device after a  

 

recent surgical procedure, because stimulation may disrupt  

 

the healing process.

11) Use caution if stimulation is intended to be applied over  

 

the menstruating or pregnant uterus.

12)  For single patient use only.

Содержание Eco-Stim NC89481

Страница 1: ...Instruction Manual Be sure to read this instruction manual before operating device Keep manual in a safe place NC89481 Eco Stim TENS EMS...

Страница 2: ...hat the device complies with the following normative documents IEC60601 1 IEC60601 1 2 IEC60601 1 11 IEC60601 2 10 IEC62304 ISO10993 5 ISO10993 10 ISO10993 1 ISO14971 QUICK REFERENCE GUIDE 4 1 FOREWOR...

Страница 3: ...ent Press ON OFF M button to stop treatment and return to the standby mode QUICK REFERENCE GUIDE Please read the instruction manual completely before attempting to use this device Steps 1 3 should be...

Страница 4: ...ds us that something is wrong without which abnormal conditions may go undetected causing damage or injury to vital parts of our bodies 1 FOREWARD Pain does not occur until encoded messages travel to...

Страница 5: ...cose veins etc 2 SAFETY INFORMATION 4 Electrode placements must be avoided in the carotid sinus area anterior neck or transcerebrally through the head 5 This device should not be used in overly enerva...

Страница 6: ...act with each other 19 Keep the stimulator out of reach of children 20 Consult your doctor if you have any questions 21 Discontinue use and do not increase the intensity level if you feel discomfort d...

Страница 7: ...proper use may be dangerous 15 Rare cases of skin irritation may occur at the site of the electrode placement following long term application 16 Do not use this device in the presence of other equipme...

Страница 8: ...ing mode press the button to unlock the keys In setting mode press the button to decrease the corresponding data for the pulse rate pulse width or treatment time 5 button In standby or treatment mode...

Страница 9: ...ams P W Pulse Width 100 300 s P R Pulse Rate 2 100Hz Hz vibration per second Treatment time 5 90 minutes Number of programs 8 programs P W Pulse Width 100 300 s P R Pulse Rate 2 100Hz Hz vibration per...

Страница 10: ...the connector into the port on the top of the device Ensure the electrode wires are inserted correctly The device has two output ports controlled by Channel A and Channel B at the top of the unit You...

Страница 11: ...ice or the appropriate channel first in order to avoid unwanted irritation 5 It is recommended that at minimum 1 97 x 1 97 self adhesive square electrodes are used at the treatment area 6 Never remove...

Страница 12: ...1 2 2 1 1 2 1 2 1 2 1 2 23 22 Arm Hand Back Abdomen Hip Leg Foot Foot Joint knee Joint elbow Joint ankle Joint wrist Neck Shoulder Position of electrode placement under EMS programs...

Страница 13: ...isplays as follows 6 3 Select treatment program Based on your needs press P button to select the treatment program The LCD displays as follows 6 INSTRUCTIONS FOR USE 6 4 Set program parameter Press an...

Страница 14: ...dby mode 6 5 Start treatment Press the button of CH1 to increase the channel 1 intensity press the button of CH2 to increase the channel 2 intensity The LCD displays as follows 6 6 Adjust the output i...

Страница 15: ...nd contact a physician right away 3 Batteries must not be charged dismantled or short circuited 4 Protect batteries from excess heat Take the batteries out of the device if they are spent or you will...

Страница 16: ...hile the device is still on 3 Only use the electrode pads recommended by the manufacturer Use of inferior electrode products could result in injuries to the user 6 11 Where do I attach electrode pads...

Страница 17: ...before use 4 Check your allergic history Change the electrode location or shorten the treatment time If your skin is over sensitive stop the treatment or see a doctor 33 32 4 Clean the surface of the...

Страница 18: ...isconnect the lead wires from the electrodes 3 Place the electrodes onto the plastic film and store in the sealed package 4 Wrap the lead wires and store in the sealed package 9 2 Storing the Unit 1 P...

Страница 19: ...f a typical location in typical commercial or hospital environment NOTE UT is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic immun...

Страница 20: ...r W Distance m Immunity TestLevel V m 385 380 390 TETRA 400 Pulse modulationb 18Hz 1 8 0 3 27 450 430 470 GMRS 460 FRS 460 FMc 5kHz deviation 1kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modula...

Страница 21: ...or invoice 2 Repairs under warranty should be in the warranty period for the device 3 The following cases are excluded under the warranty All damages that arise due to improper operation e g nonobserv...

Страница 22: ...43 42 USER NOTES...

Страница 23: ...orth Coast Medical Inc www ncmedical com Manufactured for North Coast Medical Inc 780 Jarvis Drive Suite 100 Morgan Hill CA 95037 U S A Made in China REV89481i_0521 Instruction Manual Eco Stim TENS EM...

Отзывы: