Guidance and manufacturer’s declaration — electromagnetic immunity
The device is intended for use in the electromagnetic environment specified
below. The user of the device should assure it is used in such environment.
Immunity test
IEC 60601 Test
level
Compliance
level
Electromagnetic
environment - guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
±8kV direct
& indirect
contact;
±15kV air
discharge
±8kV direct
& indirect
contact;
±15kV air
discharge
Floors should be wood,
concrete or ceramic tile.
If floors are covered with
synthetic material, the
relative humidity should
be at least 30%.
Electrical fast
transient/burst
IEC 61000-4-4
±2 kV for power
supply lines
not
applicable
not applicable
(for internally powered
equipment)
Surge IEC
61000-4-5
± 1 kV line(s) to
line(s)
not
applicable
not applicable
(for internally powered
equipment)
Voltage dips,
short
interruptions
and voltage
variations on
power supply
input lines
IEC 61000-4-11
<5% U
T
(>95% dip in U
T
)
for 0.5 cycle
40% U
T
(60% dip in U
T
)
for 5 cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
<5% U
T
(>95% dip in U
T
)
for 5 sec
not
applicable
not applicable
(for internally powered
equipment)
Power frequency
(50Hz/60Hz)
magnetic field
IEC 61000-4-8
10V/m
10V/m
Power frequency
magnetic fields should
be at levels characteristic
of a typical location in
typical commercial or
hospital environment.
NOTE:
U
T
is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer’s declaration — electromagnetic immunity
The device is intended for use in the electromagnetic environment specified
below. The user of the device should assure it is used in such environment.
Immunity test IEC 60601
Test level
Compliance
level
Electromagnetic
environment - guidance
Radiated RF
IEC 61000-4-3
10V/m
& table 9
10V/m
& table 9
Portable and mobile RF
communications equipment
should be used not closer to
any part of the device, including
cables, than the recommended
separation distance calculated
from the equation applicable to
the frequency of the transmitter.
Recommended separation distance
80 MHz to 800 MHz
800 MHz to 2.5 GHz
Where
P
is the maximum output
power rating of the transmitter
in watts (W) according to the
transmitter manufacturer and
d
is the recommended separation
distance in meters (m).
Field strength from fixed RF
transmitters, as determined by
an electromagnetic site survey
a
,
should be less than the compliance
level in each frequency range
b
.
Interference may occur in the
vicinity of equipment
marked with the
following symbol:
NOTE 1
At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
37
36