NOTES:
1
USE 1" PIPING.
2
PUMP IS IN IDU.
3
ONLY R-W AND R-Y CONTROL REQUIRED.
4
ONE STAT CALL AT A TIME, INSTALL MUST INTERLOCK.
5
FOR COOLING, ALL CHILLED WATER PIPING MUST BE INSULATED.
6
SEE P.1 FOR RELIEF VALVE.
NORAIRE AIR TO WATER HEAT PUMP
- Add cooling forced air water coil, see sheet 3.
- M
ust size to m
a
tch heat pum
p BTU/h
- W
a
ter coil not configured for heating, see sheets 9 & 10
- Heating uses standard electric water heater as the tank.
- Suggest 35,000 BTUh m
a
xim
u
m
load capacity. For larger
system
s, m
u
st use sheet 6, type buffer tank.
HX103
Rev. 08 6/16/2014
Sheet 4 of 12
(TANK)
IDU
HEATER
ELECTRIC WATER
5
1
AQUASTAT
W
2
ZONE STATS
CONTROLLER
ODU
ZONE
3
ZONE CONTROLLER, & NOTE 4. SEE SHEET 12.
G
Y
ELECTRO HP-BTC CAN REPLACE AQUASTAT,
STAT
AIR
6