05/16/2014 21
NI216
Operation Indicators
Front Panel
POWER ON
– power supply and housekeeping
On – normal
Fast pulsing –
ACD
is timing
Slow pulsing – alarm is
Hard Hold
Fast pulsing and STATUS LED – mode D position, not used,
incorrect setting
HP ODU
– HP-Y wire is high
AQUASTAT
– calling
DEFROST
– On when ODU is in defrost
STATUS –
internal circuit arrangement, can only be one at a time
Heat or Cool or Boiler (backup)
On-peak – will appear when there is a utility interrupt
and
when
the PC setup is configured for such input
SERVICE –
this is an auto reset function but the ODU (compressor) is interrupted for 6 minutes (two PC setup
ACD’s). See Field Setup or Programming section.
Cooling – the water temperature is below a setup limit
Heating – the water temperature is above this setup limit
HI pressure – over 500 psig
Low Water Flow – using temperature differential (PC setup value), the water flow appears to be low,
evaluate pump/piping design or water flow has been restricted
ALARM
These conditions are more serious, there are two tries and on the consecutive third the ODU
(compressor) is shut down (Hard Hold). Depending upon the mode selection the system will
automatically go to
backup
for continued heating. There is no backup for cooling. To prevent
continuous use of the electric boiler, troubleshooting or service should be initiated as soon as possible.
See Troubleshooting section for additional pulse out details.
NOTE:
Repeated cycling on any of these limit conditions will eventually cause permanent damage. If it is
an ALARM condition, do not recycle the aquastat (W or Y), the LED pulses should be adequate to provide
information to the service technician. ALARM conditions represent potential damage to internal
components.
Boiler override –
applies to modes B and C only, has no function for mode A. This allows the user to select
Boiler heating and turns off the heat pump (ODU). Note: This is heating only, for cooling the switch must be in
the HP position.
Control Board, Back Panel
Boiler stages – four red LED’s, bottom left next to J1
Boiler automatic hi-limit, hardware vessel temp – red LED opposite J2
Содержание NC-FE series
Страница 22: ...05 16 2014 20 NI216 ...
Страница 49: ... 0 1 2 3 4 5 6 3 0 1 40 1 5 3 1 7 8 8 4 5 43 15 ...
Страница 50: ... ...
Страница 51: ... ...
Страница 52: ... ...
Страница 53: ... ...
Страница 54: ... ...
Страница 55: ... 01 2 ...
Страница 56: ... 0 0 1 0 2 1 3 4 4 5 0 6 ...
Страница 57: ... ...
Страница 60: ......
Страница 63: ...XX036 ...
Страница 64: ...XX036 ...