15
6.3
Input Module
1.
Install the input module (E03) on the sprayer near the NORAC valve block. Secure it to
the boom with cable ties.
2.
Connect the free end of the CANbus cable (C02) from the valve module to the input
module.
3.
Insert the 12 pin plug (P02) into the
OEM 3
connector on the end of the input module.
4.
Connect the 12 pin connector on the tilt interface cable (C20) to the
Thru 2
connector on
the side of the input module.
5.
Connect the 12 pin connector on the main lift interface cable (C21) to the
Thru 1
connector on the side of the input module.
6.
Insert the connectors on C21 into the connectors on the Relay Module (AGCO Part
Number: 121749).
7.
Insert the connectors on C20 into the VG solenoid connectors on the Rogator wiring
harness.
Figure 18: Input Module Connections