11
4.3
W
ING
S
ENSOR
I
NSTALLATION
1.
Mount the Low Profile Sensor Mounting
Brackets (
B20
) onto the boom as show
in
Figure 4
and
Figure 5
with the
mounting base in front of the tube.
Figure 4: Low Profile Bracket
Mounting
Figure 5: Low Profile Bracket
Mounted on Boom
If possible, mount the sensor
brackets while the booms are in
their folded position to ensure
that they will not interfere with
anything when the boom is folded
for transport.
Mounting the sensor bracket to
the break-away section of the
boom may cause the boom to
drop suddenly as a break-away
occurs. This will occur on break-
away sections which lift as they
break away.
For optimal boom tip protection,
it is recommended that the
sensor be mounted within
approximately two feet (60cm) of
the boom tip.
Please refer to the UC4+ system
warranty at the end of the
UC4+
Sprayer Boom Control Operator’s
Manual
(
M01
) for implications.
2.
Mount the NORAC UC4+ ultrasonic
sensors (
E02
) into the sensor brackets.
The sensors should be oriented forward
(ahead) of the boom.
When installing the UC4+
sensors (E02), start with the
smallest serial number on the left
hand side proceeding to the
largest serial number on the right
hand side (Figure 9).
3.
Sensor cables should run either through
hole in the back or through the side
cut-out and behind the bracket. Ensure
the cable is clear of moving parts and
will not be damaged during folding.
Cable-tie the connector in place. The
cable must not hang below the boom.
Front
Содержание UC4 Plus Rogator 64 Series
Страница 10: ...8 Figure 3 Hydraulic Plumbing Schematic ...
Страница 25: ...23 Figure 26 Load Sense Plumbing on some JD4710 Rear of Sprayer Front view of block H06 F03 ...
Страница 26: ...24 Figure 27 Load Sense Line Connection to John Deere Combination Valve Block H06 F03 Rear of Sprayer ...
Страница 27: ...25 Figure 28 2003 Load Sense Line Connection H06 F03 ...
Страница 35: ...33 5 3 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Страница 36: ...34 5 4 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Страница 37: ...35 5 5 ITEM C04 44651 CABLE VALVE EXTENSION ...
Страница 38: ...36 5 6 ITEM C10 44650 14 CABLE UC4 POWER BOOM CONTROL JOHN DEERE ...
Страница 39: ...37 5 7 ITEM C12 44658 01 CABLE UC4 VALVE BC JD ...
Страница 41: ...39 Figure 37 Cable C12 44658 01 BEFORE Modification ...
Страница 42: ...40 Figure 38 Cable C12 44658 01 AFTER Modification ...