background image

6

598-1286-01

Note:

  When first turned on wait about 1 

1

/

2

 minutes for 

the circuitry to calibrate.

* resets to Auto Mode at dawn.

  Least Sensitive 

 Most Sensitive

The sensor is less sensitive to motion directly towards it 

and more sensitive to motion across coverage area.

Sensor

Motion

Motion

OperatiOn

Mode:

On-Time

Works:

Day

Night

test

5 Seconds

x

x

auto

1, 5, or 10

Minutes

x

Manual

To Dawn*

x

MANUAL MODE

AUTO

TEST

ON-TIME  Switch  at  1,  5,  or  10 

minutes

... back on.

1 Second OFF 

then

...

Manual mode only works at night 

because daylight returns the sensor 

to AUTO.
Flip the light switch off for one sec-

ond then back on to toggle between 

AUTO and MANUAL MODE.
Manual mode works only with the 

ON-TIME  switch  in  the  1,  5,  or 

10 position.

MODe sWitching suMMary

Flip light switch off for one 

second then back on*

* If you get confused while switching modes, turn the power 

off for one minute, then back on. After the calibration time 

the control will be in the AUTO mode.

ManuaL MODe

aDjustMent OF cOverage area

The sensor on this light fixture detects “motion” by the 

movement  of  heat  across  the  coverage  area.  However, 

following are examples of objects that also produce heat 

and can cause the sensor to trigger:

• Pools of Water 

• Air Conditioners

• Dryer Vents 

• Animals

• Heating Vents 

• Automobile Traffic

If you suspect that a heat source of this type is triggering 

the sensor, reduce the sensitivity.

speciFicatiOns

Range ...............................Up to 30 ft. (9.1 m) [varies with 

surrounding temperature].

Sensing Angle...................180°

Electrical Load .................Up  to  100  Watt  Maximum 

Tungsten Incandescent

Bulb Type .........................Medium Base, Type “A”, 100 

Watt Maximum

Sensor Capacity ................360 Watt (3.0 A) Maximum 

Tungsten Incandescent

Power Requirements .........120 VAC, 60 Hz

Operating Modes .............TEST, AUTO, and MANU-

AL MODE

ON-Timer ........................1, 5, 10 minutes

Test Timer ........................5 Seconds

Manual Mode Timer ........Dusk-to-Dawn

Содержание Carriage Light with Motion-activated 52-4473-6

Страница 1: ...Attachreceiptincaseofpossible warranty issues Model Number Requirements The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Someelectrica...

Страница 2: ...er lights from the motion sensor see Optional Wiring Note All wiring must be run in accordance with the Canadian Electrical Code through conduit or another acceptable means Contactaqualifiedelectricia...

Страница 3: ...ith the bare fixture wire and the box ground wire Secure with a wire connector Secure the other end of the pigtail with the GND screw on the X bar Black to black White to white Ifyouhavemetaljunctionb...

Страница 4: ...hite wires together Total fixture ratings must not exceed 360 Watts 3 0 A Wiring Diagram 2 When wiring to control another motion sensing light fixture Master Slave Strip the red wire in both light fix...

Страница 5: ...ing section 5 SettheamountofON TIMEyouwantthelighttostay on after motion is detected 1 5 or 10 minutes Maximum Range Maximum Coverage Angle Top View Final Assembly 1 Push the wires into the junction b...

Страница 6: ...If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode MANUAL MODE Adjustment of Coverage Area The sen...

Страница 7: ...y dark location 2 Light control is in TEST 1 The fixture is operating normally under these condi tions 2 Set control switch to 1 5 or 10 minutes Lights come on for no apparent reason 1 Light control m...

Страница 8: ...tre reli e un interrupteur Dans certaines localit s le code de l lectricit exige que l installation soit confi e un lectricien quali fi Veuillez v rifier les codes en vigueur dans votre r gion Avant l...

Страница 9: ...teurdemouvement voir C blage Facultatif Note Le c blage doit tre conforme aux exigences du Code canadien de l lectricit et tre install dans des canalisations ou autres dispositifs acceptables Si vous...

Страница 10: ...re et lefildeterredelabo tedejonction Utilisezunserre fils Fixez l autre extr mit de la queue de cochon avec la vis de terre GND sur la plaque de montage noir noir blanc blanc Si la bo te de jonction...

Страница 11: ...age 2 C blage d un autre luminaire d tecteur de mouvement Ma tre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de commande ma tre aux fils rouge et noir du lumi...

Страница 12: ...un mouvement 1 5 ou 10 minutes Note Le capteur exige 1 1 2 minute avant de d tecter les mouvements Lors de la premi re mise sous tension attendez 1 1 2 minute Port e maximale Angle de couverture maxi...

Страница 13: ...nde plus en circuit pour alterner entre les modes AUTO et MANUEL Lemodemanuelnefonctionne que lorsque l interrupteur ON TIME est aux positions 1 5 ou 10 R sum du mode de commutation Mettrel interrupte...

Страница 14: ...e 2 Le r glage de port e est trop lev 1 R duisez la port e 2 R duisez la port e L clairage demeure al lum continuellement 1 Lecapteurpeutpercevoirunesourcedechaleur comme une sortie d air un vent de s...

Страница 15: ..._ __________________________________ __________________________________ __________________________________ __________________________________ __________________________________ _______________________...

Страница 16: ..._ __________________________________ __________________________________ __________________________________ __________________________________ __________________________________ _______________________...

Отзывы: