Intermatic FL150HPS Скачать руководство пользователя страница 1

FOR OUTDOOR USE ONLY

NOT FOR USE IN HAZARDOUS ATMOSPHERES

IMPORTANT:      Read instruction sheet carefully before installing fixture.

Retain instructions for future reference.

ELECTRICAL REQUIREMENTS

A qualified electrician should complete all required wiring. This fixture will accept 120, 208, 240 or 277 

volts AC and must be properly grounded for safety. A mounting suitable for outdoor use and rated for 

wet locations is required. Follow all applicable electrical codes and regulations.

WARNING: Electric shock hazard

Disconnect power at circuit breaker or fuse box before installing or servicing light.

WARNING: Fire hazard

USE MIN 60ºC SUPPLY CONDUCTORS.

CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY.

Lamp and housing become very hot during use.

Ensure free air circulation around unit to dissipate heat.

Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect.

Avoid locations where humans or animals might accidentally touch fixture.

WARNING: Explosion hazard

Never operate light without securing the lens door. When light is operating, the gas in the 

lamp inner arc tube is at high pressure.

Never operate light if the fixture lens or outer glass envelope of the lamp is broken or missing.

WARNING: Explosion hazard

Wear safety glasses and gloves when handling lamp, High Pressure Sodium outer envelope is under

vacuum and could implode. 

MOUNTING & WIRING

1. Screw the threaded mounting arm of the fixture into 1/2” NPS mounting hole on mounting device.

Tighten locknut to secure fixture. See Figure 1.

Figure 1

Figure 2

Mounting 

Arm Bolt

Locknut

Lens 

Door

Screw

Reflector

Screw

Lampholder

Install with Lamp vertical

HID Flood Light - FL Series

INSTALLATION INSTRUCTIONS

Lamp Types: High Pressure Sodium 150 Watt

Model: FL150HPS

Отзывы: