background image

 

START-S4XL

ST

ART

-S4XL_2901

13_VXX13_GB                 

 

 

 

www

.ebtechnology

.it 

 

  www

.nologo.info

FUSE 5A

FUSE 200mA

 1  2  3  4  5  6  7  8  9 10

 1     2    3

 4    5    6    7    8    9   10  11

12  13  14  15 16  17  18  19 20  21  22  23  24  25

 1  2  3  4  5  6  7  8  9 10

230V

ac

20

40

60

80

100

0

2

6

8

MAX

4

10

MIN

2

6

8

OFF

4

10

FORCE

PhASE 

DISPLACEMENT

SLOW 

DOWN

TIMES

CODE

DIP A

DIP B

Reset of the control board:

Press button “CODICI” and “TIMES” 

for 10 seconds

OPEN

CLOSE

CODES

230 V

ac Phase

230 V

ac Lamp

230 V

ac Lamp

Motor 1 COMMON

Motor 1 OPEN 

Motor 1 CLOSE

Motor 2 COMMON

Motor 2 OPEN

Motor 2 CLOSE

Open. Limit Switch Mot. 2

Clos. Limit Switch Mot.1

Closing photocell

Start Button

24V

ac

24 V

ac/12V

ac elect. lock

12V

ac electrical lock

ST

OP

PEDONALE Botton

Photocell always working

COMMON contacts -

A

Earth -wire

Light / Lamp.

Light / Lamp.

Fototest 24V

ac

12V

ac

24Vdc +

COM

  24Vdc -

 26  27  28  29  30  31

 1  2  3  4  5  6  7  8  

DIP  C

Remove of the inputs

• 

Single phase for 230 Vac 2 motors

• 

Universal control unit for 1 or 2 motors swing

• 

4 limit switches

• 

Separate slow down

Clos. Limit Switch Mot. 2

Open. Limit Switch Mot.1

433,92 Mhz Radio-decode

Radio-receiver

Содержание START-S4XL

Страница 1: ...230 Vac Lamp Motor 1 COMMON Motor 1 OPEN Motor 1 CLOSE Motor 2 COMMON Motor 2 OPEN Motor 2 CLOSE Open Limit Switch Mot 2 Clos Limit Switch Mot 1 Closing photocell Start Button 24Vac 24 Vac 12Vac elec...

Страница 2: ...ical limit switches should fail or during manual operations 2 Installation 1 Introduction START S4XL is the ongoing evolution of the START S4 electronic control unit completely compatible and equipped...

Страница 3: ...75 mm2 Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit Do not connect the cables in underground cases even if they are water tight...

Страница 4: ...OPEN M2 M 2 Closing 11 Output to connect motor no 2 pole CLOSE FCC M2 12 Input Closing limit switches motor no 2 FCA M2 13 Input Opening Limit Switches 2 FCC M1 14 Input for Closing limit switches of...

Страница 5: ...and if adjusted at the maximum power the door opens when the second door has finished the working time In next opening will the new value valid 0 Max SPEED SLOW DOWN Setting up of the speed of the sl...

Страница 6: ...8 9 10 1 2 7 3 ON REVERSING STROKE This function starts a closing thrust at the beginning or at the end of the manoueuvre to make easy the work of the electrical lock 4 ON Courtesy light In the output...

Страница 7: ...pening displacement will be at 2 seconds The closing displacement can be chosen with the trimmer displacement 7 X Leave in the OFF 8 OFF Time learning planned from the user Leave in OFF when used the...

Страница 8: ...put photocell always activated 8 ON Radio DECODE It activate the radio receiver 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7...

Страница 9: ...ry all codes is possible only when the gate is closed 1 Make sure that the gate is in closed position 2 Push the codes button until the L E D CODICE flashes AND release it Wait until the reset of the...

Страница 10: ...nt time the first motor closes 5 Press the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switc...

Страница 11: ...switch of motor no 2 is not available The second motor stops the first motor CLOSES 9 a if the limit switch is available wait until motor no 2 stops The motor no 2 stops motor no 1 closes 10 Push the...

Страница 12: ...ls for the TEST function Now the control unit check the TEST function of all devices and the the gate opens with a little bit delayed 8 6 9 10 7 8 Make all connections to the TEST as shown in the manu...

Страница 13: ...989 harmonizing the legislation of the member countries regarding electromagnetic compatibility Reference to harmonized standards EN 61000 6 2 EN 61000 6 3 THE PRODUCT COMPLIES with the essential requ...

Страница 14: ...sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 14 06 2007 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der Unterzeichner be...

Отзывы: