The purpose of this alignment is to tune the carrier signal (at marker 2) and the +67kHz
signal (at marker 3) to a minimum level.
Use the variables 'TX I DC offset' and 'TX Q DC offset' to adjust the carrier signal to a
minimum level (marker 2). Tuning is possible by using arrow keys on the keyboard. Push-
ing the sliders by using the mouse is less sensitive but even possible.
After tuning to the minimum the level difference between marker 2 and the peak levels
at marker 1 must exceed 40dB.
The Spectrum Analyzer now shows a plot like this:
Use the variables 'Amplitude difference' and 'Phase difference' to adjust the +67kHz sig-
nal to a minimum level (Marker 3). Tuning is possible by using the arrow keys on the key-
board. Pushing the sliders by using the mouse is less sensitive but even possible.
After tuning to the minimum the level difference between marker 3 and the peak level at
marker 1 must exceed 40dB.