RH-6
Company Confidential
7 - RF Description & Troubleshooting
CCS Technical Documentation
Page 72
Copyright
©
2003 Nokia Corporation.
Issue 1 10/2003
Company Confidential
Select again in the RF controls window:
Select
TX Power Level 4
The setup should now look like this:
The Spectrum Analyzer now shows a plot like this:
Ref Lvl
35 dBm
Ref Lvl
35 dBm
RBW
3 kHz
VBW
3 kHz
SWT
3 s
RF Att
30 dB
30 kHz/
Center 1.88 GHz
Span 300 kHz
27.5 dB Offset
A
1MA
Unit
dBm
-60
-50
-40
-30
-20
-10
0
10
20
30
-65
35
1
2
3
Marker 3 [T1]
-12.20 dBm
1.88006771 GHz
3 [T1] -12.20 dBm
1.88006771 GHz
1 [T1] 27.81 dBm
1.87993229 GHz
2 [T1] 4.13 dBm
1.88000000 GHz
Date: 15.JAN.2002 10:53:47