Company Confidential
After tuning to the minimum the level difference between marker 2 and the peak levels
at marker 1 must exceed 40dB.
The Spectrum Analyzer now shows a plot like this:
Use the variables 'Amplitude difference' and 'Phase difference' to adjust the +67kHz sig-
nal to a minimum level (Marker 3). Tuning is possible by using the arrow keys on the key-
board. Pushing the sliders by using the mouse is less sensitive but even possible.
After tuning to the minimum the level difference between marker 3 and the peak level at
marker 1 must exceed 40dB.
Ref Lvl
35 dBm
Ref Lvl
35 dBm
RBW
3 kHz
VBW
3 kHz
SWT
3 s
RF Att
30 dB
30 kHz/
Center 897.4 MHz
Span 300 kHz
27.5 dB Offset
A
1MA
Unit
dBm
-60
-50
-40
-30
-20
-10
0
10
20
30
-65
35
1
2
3
Marker 1 [T1]
33.65 dBm
897.33229000 MHz
1 [T1] 33.65 dBm
897.33229000 MHz
2 [T1] -19.54 dBm
897.40000000 MHz
3 [T1] -10.79 dBm
897.46771000 MHz
Date: 14.JAN.2002 13:20:36