RH-6
Company Confidential
7 - RF Description & Troubleshooting
CCS Technical Documentation
Page 38
Copyright
©
2003 Nokia Corporation.
Issue 1 10/2003
Company Confidential
Press Calibrate and a window pops up:
Connect an external signal generator to the RF connector of the phone and set the gen-
erator as told in the window, taking care for external cable losses. If a radio communica-
tion tester (CMD55, CMU200, 8960, MT8801) is used, be sure to have it running in
continuous mode and with modulation switched off.
Press OK and the window closes.
A typical result will look like this: