RH-6
Company Confidential
7 - RF Description & Troubleshooting
CCS Technical Documentation
Page 54
Copyright
©
2003 Nokia Corporation.
Issue 1 10/2003
Company Confidential
a window pops up:
Press Yes and the EGSM RX Band Filter Response Compensation is finished.
Limits
Regarding limits the value for N4 is given here. For the other filter frequencies please
have a look to Appendix A where all FLALI test cases are listed together with the limits.
RX channel select filter calibration
This calibration is calibrating the Baseband filter inside Mjoelner. It is done by internally
measuring a prototype filter, for this reason the calibration is done once, not separately
in 3 bands.
Set operating mode to local mode
Select
Maintenance
Alt-M
Tuning
T
RX Channel Select
H
filter Calibration
A window pops up:
Select Yes and the RX Channel Select Filter Calibration window pops up.
Value
Typical
Limit
min.
Limit
max.
N4
0
-0.3
0.3