7368 ISAM ONT G-240W-G Product Guide
Install a G-240W-G indoor ONT
Issue: 01
3FE-47555-AAAA-TCZZA
63
6
Connect the fiber optic cable with SC/APC adapter into the SC/APC connector; see Figure
for the location of the SC/APC connector.
7
Install the power supply according to manufacturer specifications.
8
Connect the power cable to the power connector.
9
Power up the ONT unit by using the power switch.
10
If used, enable the Wi-Fi service.
i
Locate the WLAN button on the ONT; see Figure
for location of the WLAN button.
ii
Press the WLAN button to change the status of the Wi-Fi service.
11
Verify the ONT LEDs, voltage status, and optical signal levels; see the
7368 Hardware and
Cabling Installation Guide
.
12
Activate and test the services; see the
7368 Hardware and Cabling Installation Guide
.
13
If used, configure the SLID; see the
7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide
.
Danger —
Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning —
Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius
in the cable can result in damage to the optic fiber.
Note —
Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC fiber
optic pigtail cable.
Note —
Observe the following:
•
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12VDC, 3A.
Release 05.08.01a | August 2018 | Edition 01