7368 ISAM ONT G-240W-G Product Guide
ONT configuration file over OMCI
Issue: 01
3FE-47555-AAAA-TCZZA
167
FILENAME2 will be downloaded and FILENAME2 will be made passive. An ONT reboot
is not required.
iv
If
pland-cfgfileX=FILENAME3
and
dnload-cfgfileX= FILENAME 4
, the OLT
reports an error because the filenames are not the same.
v
Configure equipment interface …
pland-cfgfile1=XMLXXXXXX1
and
dnload-cfgfile1 XMLXXXXXX1
Configure equipment interface …
pland-cfgfile2=XMLXXXXXX2
and
dnload-cfgfile2 XMLXXXXXX2
Although the OLT permits the above two steps without reporting an error, Nokia does
not recommend executing them, because the ONT may exhibit unexpected behavior.
vi
If
pland-cfgfileX=Auto
and
dnload-cfgfileX= Auto
The OLT will download the XML file from "sw-ctr-list" (
configure equipment ont
sw-ctrl
)
4
STOP. This procedure is complete.
The ONT will distribute the configuration files to the different services based on the active
indication from the OLT and on the Nokia defined index.
The ONT automatically reboots to apply the configuration files. After the ONT reboots and reports
the active version, the OLT completes the file download procedure.
Operators must check the committed file from the OLT to verify whether the corresponding file has
been applied. If an error occurs, contact Nokia for support.