G-240W-G unit data sheet
40
7368 ISAM ONT G-240W-G Product Guide
3FE-47555-AAAA-TCZZA
Issue: 01
4.2.7
TR-104 voice-related alarms
The G-240W-G ONT supports the following four TR-104 voice-related alarms on a
per FXS port basis.
These alarms all represent SIP registration failures with an alarm level of MAJOR.
•
SIPREGDNS: domain name could not be resolved
•
SIPREGAUTH: authentication failed
•
SIPREGTO: re-transmissions timed out
•
SIPREGERFRSP: error response from the registration server
4.2.8
TR-104 parameters for FX line testing
New attributes have been added to the TR-104 Voice Service object structure to
enable the ACS to perform line tests. The ONT supports the following electrical line
tests:
•
hazardous potential
•
foreign electrical motive force
•
resistive faults
•
receiver off-hook test
•
ringers test
4.2.9
TR-111 support
The G-240W-G ONT supports TR-111, which extends the WAN Management
Protocol defined in TR-069 to enhance the ability to remotely manage LAN devices.
The device-gateway association enables an ACS to identify the associated gateway
through which a device is connected.
A connect request via the NAT gateway enables an ACS to initiate a TR-069 session
with a device that is operating behind a NAT gateway.
4.2.10
TR-181 parameter support
TR-181 parameter support has been introduced or enhanced for the parameter
categories and functions listed in Table
For details about which parameters are supported, see your Nokia representative.
Release 05.08.01a | August 2018 | Edition 01