7368 ISAM ONT E-240W-A Product Guide
Replace an E-240W-A indoor ONT
Issue: 01
3FE-46974-AAAA-TCZZA
59
6.6
Procedure
Use this procedure to replace an E-240W-A indoor ONT.
1
Deactivate the ONT services at the P-OLT.
i
Use the RTRV-ONT command to verify the ONT status and the associated services.
Record the serial number of the ONT displayed in the command output.
Example:
RTRV-ONT::ONT-1-1-1-1-1;
ii
If the ONT is in service, place the ONT in OOS state.
Example:
ED-ONT::ONT-1-1-1-1-1;
2
If used, disable the Wi-Fi service by pressing the WLAN button; see Figure
of the WLAN button.
Figure 17
E-240W-A indoor ONT connections
3
Power down the unit by using the on/off power switch.
4
Disconnect the POTS, Ethernet, and power cables from the ONT; see Figure
for the
connector locations on the E-240W-A indoor ONT.
ON/OFF
POWER
USB2
USB1
LAN4
LAN3
LAN2
LAN1
TEL1
TEL2
WLAN
RESET
WPS2.4G
WPS5G
W
a
ll
mo
u
nting
hole
W
a
ll
mo
u
nting
hole
POT
S
port
s
(2)
(RJ-11)
Ethernet
port
s
(4)
(RJ-45)
U
S
B
port
s
(2)
Wi-Fi
s
ec
u
rity
bu
tton
s
2.4G
a
nd 5G
Re
s
et
bu
tton
Power
inp
u
t
Fi
b
er optic
port
Wirele
ss
on/off
bu
tton
On/off
bu
tton
25272