Install an E-240W-A indoor ONT
56
7368 ISAM ONT E-240W-A Product Guide
3FE-46974-AAAA-TCZZA
Issue: 01
7
Install the power supply according to manufacturer specifications.
8
Connect the power cable to the power connector.
9
Power up the ONT unit by using the power switch.
10
If used, enable the Wi-Fi service.
i
Locate the WLAN button on the ONT; see Figure
for location of the WLAN button.
ii
Press the WLAN button to change the status of the Wi-Fi service.
11
Verify the ONT LEDs, voltage status, and optical signal levels; see the
7368 Hardware and
Cabling Installation Guide
.
12
Activate and test the services; see the
7368 Hardware and Cabling Installation Guide
.
13
If used, configure the SLID; see the
7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide
.
14
If necessary, reset the ONT.
i
Locate the Reset button on an E-240W-A indoor ONT as shown in Figure
.
ii
Insert the end of a straightened paper clip or other narrow object into the hole in the
Reset button to reset the ONT.
15
STOP. This procedure is complete.
Note —
Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC or
SC/UPC fiber optic pigtail cable.
Note —
Observe the following:
•
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12VDC, 2.5 A.
Release 06.00.00h | January 2019 | Edition 08