Nokia 6090 AT Command Set
53
+ER Error Control Reporting
This command controls whether or not the +ER: <type> result code is transmitted to
the DTE. The result code shows the current error control protocol type when
transparent data service is used. If enabled, the result code is transmitted at the point
after error control negotiation (handshaking). (V.25ter)
Syntax:
AT+ER=<mode>
Set reporting mode.
Default option
is 0.
AT+ER?
Query current setting.
Response is +ER: <mode>.
AT+ER=?
Show supported values.
Response is +ER: (list of supported
<mode>'s).
Parameters:
<mode>
0
error control reporting disabled
1
error control reporting enabled
+ES Error Control Selection
This command controls the V.42 error control protocol which can be used with
transparent data service (see cCBST at page 14). When mobile originated
calls are made the transparent data mode must be selected with the command
AT+CBST. The requested mode and the acceptable fallback mode of operation for
an initiated call are selected with parameters <orig_rqst> and <orig_fbk>. The third
parameter, <ans_fbk>, defines the acceptable fallback mode of operation when a call
is answered. (V.25ter)
Syntax:
AT+ES=[<orig_rqst>[,
<orig_fbk>[,<ans_fbk>]]]
Set error control parameters.
Default options
are 4, 0, 2.
AT+ES?
Query current setting.
Response is +ES: <orig_rqst>,
<orig_fbk>, <ans_fbk>.
AT+ES=?
Show supported values.
Response is +ES: (list of supported
<orig_rqst>'s), (list of supported
<orig_fbk>'s), (list of supported
<ans_fbk>'s).
Parameters:
<orig_rqst>
1
initiate call with buffered mode (flow
control used)
4
initiate MNP protocol
<orig_fbk>
0
error control optional, use buffered mode
if error control not established
2
error control required, disconnect if error
control not established
4
MNP error control required, disconnect if
error control not established
<ans_fbk>
1
error control disabled, use buffered mode
2
error control optional, use buffered mode
if error control not established
4
error control required, disconnect if error
control not established
6
MNP error control required, disconnect if
error control not established
Содержание 6090