OPERATION
Quick Clean
1500 (03–00)
15
c.
Submerge end of injector tube into a gallon
container of clean water (Figure 39).
FIG. 39
d.
Adjust spray gun to low pressure by pushing
spray nozzle outward.
e.
Turn the FORMULA ON/OFF lever to the ON
position, located at front of machine.
f.
Turn pump switch on and operate spray gun
for approximately one minute.
g.
Place cap on injector hose after flushing.
2.
Drain and rinse recovery tank thoroughly
(Figure 40).
FIG. 40
3.
Remove the float shut–off screen from recovery
tank cover and clean (Figure 41).
FIG. 41
4.
Empty any leftover water from solution tank if
storing machine for an extended period or if
transporting machine (See DRAINING TANKS).
5.
Wipe clean all accessories and replace on
machine. Inspect vacuum hoses for holes and
loose cuffs.
6.
Inspect condition of squeegee blades, replace if
necessary.
7.
Wipe clean power cord and check for damage.
Replace if necessary. Coil cord neatly after use.
8.
Clean machine with an all purpose cleaner and
damp cloth (Figure 42).
FIG. 42
9.
Inspect spray gun pattern. Clean or replace orifice
if spray pattern will not pin–point. Use a 5/64”
Allen wrench to remove orifice (Figure 43).
FIG. 43