20
Table 4: Size fuses PT 27R Table 5: Size fuses PT 36R
Rate
FU1 10
A
FU01 300
A
FU02 150A
9. TROUBLE SHOOTING
If the truck has malfunctions follow the instructions, mentioned under chapter 6.
Table 6: Trouble shooting
TROUBLE
CAUSE
REPAIR
Load can’t be lifted
Load weight too high
Lift only the max. capacity,
mentioned on the ID-plate
Battery discharged
Charge the battery
Lifting fuse faulty
Check and eventually replace the
lifting fuse
Hydraulic oil level too low
Check and eventually refill hydraulic
oil
Oil leakage
Repair the hoses and/or the sealing
of the cylinder
Oil leakage from air
breathing
Excessive quantity of oil.
Reduce oil quantity.
Truck not starts
operating
Battery is charging
Charge the battery completely and
then remove the main power plug
form the electrical socket.
Battery not connected
Connect the battery correctly
Fuse faulty
Check and eventually replace fuses
Low battery
Charge the battery
Combined emergency switch is
activated
De-activate the combined
emergency switch by insert and pull
the knob.
Tiller in the operating zone
Move the tiller firstly to the braking
zone.
If the truck has malfunctions and can’t be operated out of the working zone, jack the truck up and go with
a load handler under the truck and safe the truck securely. Then move truck out of the aisle.
Rate
FU1 10
A
FU01 350
A
FU02 150A