OPERATING PROCEDURE:
MENU >> USER SETTINGS >> THERMOSTAT TIMER
Access the menu by pressing key
Scroll the items to USER SETTINGS, key
Access the menu by pressing key
Scroll the items to THERMOSTAT TIMER, key
Access the function with the key
The screen appears with activation of the
function and the possibility of selecting 4 TIMED set-
ting programs, as in the figure.
OK
OK
OK
Edit the switch on and switch off times, as well as
enabling the days of the week, keys
Confirm each data change using the
key and pass to the second screen of the
TIMER program.
The screen, in the figure below, displays the possibili
-
ty of setting the power to the fireplace during
activation of the time slot and the temperature you
want to obtain in the ambient .
Furthermore, you can manage the ventilation speed
(if optional) you want to have at a given power .
OK
1
1
2
2
Edit the values using the keys
Confirm each data change using the
key until you exit the program.
OK
During editing, remember that:
• to return to the previous data, without saving
the last data changed, press the key
• if you intend changing a single datum, having ter
minated the change, press the key multiple
times until you exit the following function.
To return to the STAND-BY screen, use the
key , repeating the operation multiple times.
OK
11.2 AUGER LOADING FUNCTION
The following function is necessary to facilitate the
switch on phase of the appliance, after accurate
cleaning was conducted of the hopper (pellet
container) to remove sawdust which, over time,
is created on the base. See the chapter “Routine
maintenance of the product”.
Also check you have placed pellets in the tank
and that the appliance is in the “OFF” or “FINAL
CLEANING” status before starting the function.
The number expressed in seconds indicates the
rotation time of the auger during the loading phase.
After this time is up, the auger stops automatically,
after which the appliance can switch on.
OPERATING PROCEDURE:
MENU >> USER SETTINGS >> AUGER LOADING
Access the menu by pressing key
Scroll the items to USER SETTINGS with the key
Access the menu by pressing key
Scroll the items to AUGER LOADING, key
Access the function by pressing key
The cleaner activates (for models with automatic
cleaning), after which pellet loading is enabled.
The display shows the time that passes up to 0,
corresponding to loading switch off.
OK
OK
OK
OK
The appliance, at the end of loading, goes to the
USER SETTINGS screen.
Enable/disable the function with the key to dis-
play the addition or bypassing of the tick and:
• Return to USER SETTINGS with the key .
OR
• Pass, using the key , to the choice of
program to set, before accessing with the
key to change it.
If you want to access 1 of the 4 programs, the
screen presented is as follows:
OK
OK
After the initial loading phase, a appears
POPUP which indicates to suck the pellet from the
brazier. This operation does not allow emptying the
pellets in the ash drawer when the plate is rotated
during ignition.
Always vacuum the brazier using an ash cleaner,
FIRE HAZARD
.
Содержание UNICA 10 C
Страница 1: ...EN Installation use and maintenance manual UNICA 10 V C...
Страница 36: ...Use and maintenance manual Model UNICA 10 V C 36 ENGLISH MAINTENANCE DATE INTERVENTION CARRIED OUT...
Страница 37: ...Use and maintenance manual Model UNICA 10 V C 37 ENGLISH ANNOTATIONS...
Страница 38: ...Use and maintenance manual Model UNICA 10 V C 38 ENGLISH ANNOTATIONS...
Страница 39: ...Use and maintenance manual Model UNICA 10 V C 39 ENGLISH ANNOTATIONS...