10.4 VENTILATION MANAGEMENT 

(if optional)

The products of the range with optional ventilation, 

taking advantage of the natural convection system 

which guarantees a considerable amount of heat in 

the ambient, in total absence of noise. However, the 

possibility exists, by accessing the menu outlined be-

low, to enable optional ventilation according to the 

desired power.

OPERATING PROCEDURE:

 MENU >> USER SETTINGS >> VENTILATION

Access the menu by pressing key
Scroll the items to USER SETTINGS with the key  
Access the menu by pressing key
First item in the “VENTILATION” menu, key
The screen appears with adjustment of 

ventilation as in the figure below.

OK

OK

OK

OK

Confirm with key  

To return to the STAND-BY screen, use the 

key       , repeating the operation multiple times.

Edit the ventilation power, keys

   0 - ventilation disabled;

1-7 - ventilation setting range;

 PS - ventilation follows power to the fireplace  

        set on the appliance.

If the PS function is not set, the fan 

is always restricted by the power of 

the product.

11 DESCRIPTION OF THE MENU FUNCTIONS

This chapter describes the  functions of the user menu, 

useful to improve some comfort-related aspects of 

the user and/or operation of the product.

11.1 PROGRAMMABLE THERMOSTAT

With the Thermostat with timer function, you can: 

program for each day of the week automatic switch 

on and off of the product, with 4 independent time 

intervals (PROGRAM 1 - 2 - 3 - 4).

The steps are outlined below to follow, starting with 

the STAND-BY screen, to access the relevant menu.

OPERATING PROCEDURE 2:

 MENU >> USER SETTINGS >> SETTINGS >> POWERFUL

Access the menu by pressing key
Scroll the items to SET USER, key  
Access the menu by pressing key
Scroll the items to SETTINGS with the key  
Access the menu by pressing key
Scroll the items to POWERFUL with the key
On the POWERFUL menu item, key
The screen appears with adjustment of the 

setting parameters, as in the figure below.

OK

OK

OK

OK

Edit the switch on and switch off times, as well as 

enabling the days of the week, keys  

During editing, remember that:

• to return to the previous data, without saving 

   the last data changed, press the key   

• if you intend changing a single datum, having ter

   minated the change, press the key       multiple 

   times until you exit the function described in the 

   paragraph.
To return to the STAND-BY screen, use the 

key       , repeating the operation multiple times.

OK

If the time slot is set with the POWERFUL function, the 

data setting in “Enable Powerful” must be “TIMER”. If 

the value is set to "ON”, the time slot is inhibited up to 

its disabling (OFF). 

The POWERFUL function, if both the time slot and the 

manual tick are enabled, inhibits AUTO manage-

ment up to its disabling. 

Confirm each data change using the 

key       until 

you exit the SETTINGS screen.

OK

Содержание UNICA 10 C

Страница 1: ...EN Installation use and maintenance manual UNICA 10 V C...

Страница 2: ...Keep this manual in an appropriate place after reading it Improper installation maintenance and use of the product relieve the manufacturer of any liability towards people or property All rights rese...

Страница 3: ...3 Pellet loading 14 7 Description of the remote control 15 7 1 Receiver 15 7 2 Keys 15 7 3 Display 15 7 4 Flat battery 16 7 5 Icon list 16 8 Menu browsing 17 9 First start up instructions 17 9 1 Date...

Страница 4: ...ity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the manufactu...

Страница 5: ...less use wrong maintenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong inter...

Страница 6: ...aking it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negative pre...

Страница 7: ...oms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for insta...

Страница 8: ...tion In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following features the smoke outlet section must be at least double the inner sec...

Страница 9: ...ble parts such as wood etc In both cases insert adequate insulation 5 between the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in particular t...

Страница 10: ...general description or diagram or photographic documentation of the changes made to the system if intervention was necessary during installation Use of certified material with the CE mark 305 2011 pos...

Страница 11: ...ed orientation of the canalization pre drilled sheet metal side pre drilled sheet metal back Fasten the canalization kit using the 5 screws highlighted already present in the stove 3 10 ASSEMBLY OF TH...

Страница 12: ...locking its draught compromising good operation of the product and if in large quantities can catch fire It is compulsory to have a qualified chimney sweep clean and check the chimney flue and the sta...

Страница 13: ...IGHT Via Palazzolo 11 25037 Pontoglio BS Italy P iva e Cod Fisc 04222670160 S MATERIA PRIMA RAW MATERIAL A B C D E F 5 5 4 4 3 3 2 2 1 1 TUTTI GLI SVILUPPI FORNITI IN FORMATO DXF SONO TEORICI IL PARTI...

Страница 14: ...s loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to cen...

Страница 15: ...ng to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequencybandsandtransmittedpowerusedbythe equipment as reported in technical documentation 868 3M...

Страница 16: ...iance see Concise icons diagram 7 4 FLAT BATTERIES If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of the handheld devi...

Страница 17: ...ing key Scroll the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and ca...

Страница 18: ...ts manual management of the optional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9 5 FIREP...

Страница 19: ...has a good energy class a fuel saving through intelligent switch off of the product reaching or required of the desired setting The procedure follows to enable the function the change of values with...

Страница 20: ...screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set the am...

Страница 21: ...stat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to follow st...

Страница 22: ...h on phase of the appliance after accurate cleaning was conducted of the hopper pellet container to remove sawdust which over time is created on the base See the chapter Routine maintenance of the pro...

Страница 23: ...and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you want to...

Страница 24: ...has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquiring the product this f...

Страница 25: ...In this case simply approach the appliance to re establish communication 12 CANALIZATION when applicable The products of the range equipped with canalization option can be equipped with single or dou...

Страница 26: ...the zone to channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the ext...

Страница 27: ...andheld device but rather from the external thermostat Having confirmed setting of the RH channelling confirm with the key and repeat the same sequence of operations for the LH channelling OK 12 5 PRO...

Страница 28: ...HASE DESCRIPTION Room settings is on MAN therefore the appliance will only work with the fireplace power as per settings never switching to saving mode MAN OP 14 FUNCTION LIST Edit the data highlighte...

Страница 29: ...orrect combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a period sets to s...

Страница 30: ...a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 06 FAULTY SMOKE EXTRACTOR No power supply to the...

Страница 31: ...roblem persists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet ta...

Страница 32: ...he following precautions switch off the product and in OFF status disconnect the power supply cable ensure all the parts are cold to touch ensure the combustion ash is completely out To clean the surf...

Страница 33: ...of embers that could still be hot and which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It ca...

Страница 34: ...are summarised in the table below PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combus...

Страница 35: ...RESSURE SENSOR FLAME PROBE SMOKE PROBE GEARMOTOR BLDC 24V SMOKE EXTRACTOR GEARMOTOR MECHANICAL CLEANER RESISTOR SWITCH ON MANUAL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET W...

Страница 36: ...Use and maintenance manual Model UNICA 10 V C 36 ENGLISH MAINTENANCE DATE INTERVENTION CARRIED OUT...

Страница 37: ...Use and maintenance manual Model UNICA 10 V C 37 ENGLISH ANNOTATIONS...

Страница 38: ...Use and maintenance manual Model UNICA 10 V C 38 ENGLISH ANNOTATIONS...

Страница 39: ...Use and maintenance manual Model UNICA 10 V C 39 ENGLISH ANNOTATIONS...

Страница 40: ...lo 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0031N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: