Use and maintenance manual - Model: “UNICA 10 V/C”
19
ENGLISH
The appearance is highlighted of the “flame” symbol
with the writing ON, without displaying the work
power.
Long press to switch off the product and reset
any alarms. The operation is accompanied by an
acoustic signal.
10 OPERATION
The products in the range include a working phase
with 7 operating power levels. The behaviour of the
appliance is described below once the setting, if set,
is reached of the ambient temperature.
10.1 SAVING MODE
During the work phase, the appliance works with the
objective of reaching the ambient temperature
set; when this condition is met, power is reduced to
SAVING mode, the phase in which fuel consumption
is minimal.
At this point, you must execute a series of precisions
to benefit the AUTO function, to pass to saving and/
or return to fully operational mode:
• Ventilation, if present and enabled, works in different
operational modes based on the existing discrepancy
between the setting and the temperature in the
premises.
• The appliance gradually increases the power to the
fireplace, as soon as the temperature in the premises
goes under the required setting (optimisation of
combustion and acoustic comfort).
Screen in SAVING mode:
10.2 COMFORT CLIMA
As described in the “saving mode” paragraph,
the appliance has the objective of meeting the
comfortable heating requirements of the user. The
function which can be enabled, linked to his mode,
also ensures, if the home has a good energy class,
a fuel saving through intelligent switch off of the
product (reaching or required of the desired setting).
The procedure follows to enable the function, the
change of values with relevant meaning, a practical
example of setting.
OPERATING PROCEDURE:
MENU >> USER SETTINGS >> COMFORT CLIMA
Access the menu by pressing key
Scroll the items to USER SETTINGS with the key
Access the menu by pressing key
Scroll the items to COMFORT CLIMA , key
On the COMFORT CLIMA menu item, key
The screen appears with activation of the
function and adjustment of the setting parameters,
as in the figure.
OK
OK
OK
Enable/disable the function with the key to
display the addition or bypassing of the tick and:
• Return to SETUSER with the key .
OR
• Pass, using the key , to the choice of time in
saving mode, before the function switches off the
product.
Edit the value with the keys
OK
Confirm the data with the key and go to
temperature setting, under which the product must
switch on.
OK
For models with an automatic cleaner, during the
switch on phase, the product activates a brazier
cleaning phase before passing to SWITCH ON. In the
event of FAILED IGNITION, after pressing the button,
a POP UP signals the need to suck the pellet from the
brazier before turning the appliance back on, thus
avoiding discharge of unburned pellets into the ash
drawer.
During first start-up of the product, unpleasant
odours may occur or smoke caused by evaporation
or drying of certain materials used. This phenomena
disappears after some hours of use. During this
period, you are advised to keep the premises well
ventilated.
Always vacuum the brazier using an ash cleaner,
FIRE HAZARD
.
Содержание UNICA 10 C
Страница 1: ...EN Installation use and maintenance manual UNICA 10 V C...
Страница 36: ...Use and maintenance manual Model UNICA 10 V C 36 ENGLISH MAINTENANCE DATE INTERVENTION CARRIED OUT...
Страница 37: ...Use and maintenance manual Model UNICA 10 V C 37 ENGLISH ANNOTATIONS...
Страница 38: ...Use and maintenance manual Model UNICA 10 V C 38 ENGLISH ANNOTATIONS...
Страница 39: ...Use and maintenance manual Model UNICA 10 V C 39 ENGLISH ANNOTATIONS...