 ENGLISH

A  “flame”  symbol  with  the  writing  ON  -  without  dis

-

playing the working power - will appear.

In order to switch off the product, as well as reset 

alarms, keep pressed key      . An acoustic signal will 

follow.

On models equipped with automatic cleaner, a brazier 

cleaning phase will be activated before entering into 

SWITCH ON mode. 

In the event of an IGNITION FAILURE after pressing      , 

a POP UP will signal the need to suck the pellet from 

the brazier before turning the appliance back on, 

thus avoiding discharge of unburned pellets into the 

ash drawer.

10 OPERATION

Products in the range include 7 different power levels. 

Below you can find a description of how the appliance 

will work once the desired room temperature - if set - is 

reached. 

10.1 SAVING MODE

While operating, the appliance works to reach the 

desired room temperature; when this condition is met, 

power is reduced and the product enters into SAVING 

mode, a phase in which fuel consumption is kept minimal.

Now, a series of clarifications on the benefits of the 

AUTO function, to switch to economy mode and/or 

return to normal operation, are made necessary:

• 

Ventilation, if present and enabled, works in 

 different operating modes, depending on the 

 

   existing discrepancy between set temperature and  

   actual temperature in the premises.

• The appliance gradually increases the fireplace 

   power as soon as temperature in the premises goes  

  below the set values (combustion optimization and 

  acoustic comfort).    

During the first activation of the product, unpleasant 

odours - or smoke caused by evaporation or drying 

of certain materials used - may occur. This phenom-

ena will disappear after some hours of use. During 

this period, it is recommended to keep the premises 

well ventilated. 

The screen in SAVING mode will appear as follows:

10.2 COMFORT CLIMA FUNCTION

As described in the “saving mode” paragraph, the ap-

pliance has the objective of satisfying the thermal com-

fort required by the user. When COMFORT CLIMA (function 

included in SAVING MODE) is active, it also ensures - if the 

house has a good energy class - a saving of fuel by 

means of intelligent switch on/off system (upon setting/

achievement of the desired temperature). Below you 

can find the procedure to activate this function and a 

thorough description of all those values which can be 

set, along with a practical example.

OPERATING PROCEDURE:

 MENU >> USER >> COMFORT CLIMA

Access menu by pressing
Scroll entries to SETTINGS with  
Access menu by pressing
Scroll entries to COMFORT CLIMA and press
Once on COMFORT CLIMA, press
The function screen with all setting parameters to be 

activated and adjusted will appear as in the figure 

below.

OK

OK

OK

Enable/disable the function by pressing          and:

• Go back to 

USER by pressing         .

                                   

OR

• Move on - by using       - to the choice of 

time in 

saving mode before the function switches off the 

product.
Edit values by using

OK

Confirm your selection by pressing       and go to 

temperature setting, to set the value under which 

the product must switch on. 

OK

Always vacuum the brazier using an ash cleaner. 

FIRE HAZARD.

Содержание B10 V ULISSE

Страница 1: ...EN Installation use and maintenance manual B10 V ULISSE...

Страница 2: ...oduct Please keep the manual in a suitable place after consulting it carefully Improper installation incorrect maintenance and or misuse of the product relieve the Manufacturer of any liability toward...

Страница 3: ...trol keys 16 7 3 Description of remote control display 16 7 4 Flat battery signalling 17 7 5 Icon overview 17 8 Menu browsing 18 9 First start up instructions 18 9 1 Hour date settings 18 9 2 Calibrat...

Страница 4: ...regular basis do not remove or bypass this devices 1 3 IMPROPER USE The product is intended to be used for the purpos es and within the limits for which it was expressly de signed for any other use th...

Страница 5: ...inted chrome plated or gold plated parts handles and electrical cables lights switch resistor indicator lights knobs and all those parts that can be removed from the fireplace e g refractory brazier c...

Страница 6: ...able and reduce the overall efficiency of the system are created Hermetic products can also be installed in the presence of forced ventilation or in premises which can go into negative pressure if com...

Страница 7: ...ian who will provide the purchaser with a Declaration of Conformity for the system and will assume complete responsibility for final installation and resulting good operation of the product In particu...

Страница 8: ...ke outlet must not be more than 3 the changes of direction must not have an angle exceeding 90 a 45 curve is recommended the section must have constant diameter equal to the output of the fireplace up...

Страница 9: ...ate if in contact with flammable parts such as wood etc In both cases please provide with adequate insula tion the space between the chimney flue and the attic 5 It is also recommended to check and co...

Страница 10: ...stem and or make sure the electrical cable to the external socket is placed safely Open the appliance by using the specific handle to be found in the box together with the instruction manual With your...

Страница 11: ...LET LOADING METHODS There are 3 possible solutions to load pellets slide the appliance open standard use the pellet drawer optional use the wall pellet loading system optional SLIDING Open the applian...

Страница 12: ...panel Re tighten the 4 screws back again to fix the drawer 1 2 1 2 HOW TO USE IT 1 2 Use the specific handle supplied to pull out the pellet drawer Start loading pellets dropping it into the hopper u...

Страница 13: ...agraph must be car ried out by authorized technical staff Remember before carrying out any maintenance operation to implement the following precautions all parts of the product must be cold ensure the...

Страница 14: ...CODE ASSIEME MODELLO CODICE FORNITORE 1 N0039 IPAV 111 65 A O 27 11 2019 DENOMINATION Propriet della Societ NOBIS S r l Senza autorizzazione scritta della stessa il presente disegno non potr essere u...

Страница 15: ...he electronic board is waiting for the remote control signal Press the confirmation key on the remote control to make the components communicate with one another A tick sign on the display accompanied...

Страница 16: ...ollows After 20 seconds of inactivity the display on the remote control blacks out and passes to SLEEP mode maintaining the remote connection with the appliance The display will re enable by simply by...

Страница 17: ...us of the appliance see Icons Overview 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display will show a symbol indi cating their limit status maintaining the functions of the remote control ena...

Страница 18: ...ER by pressing Access menu by pressing Scroll entries to SETTINGS and press Access menu by pressing Scroll entries to HOUR DATE by pressing On the HOUR DATE menu entry press The screen to adjust time...

Страница 19: ...n OFF In this case the appliance will manage autonomously only the power to the fireplace Ventilation will remain disabled 9 5 FIREPLACE POWER SETTINGS The fireplace power defines the quantity of heat...

Страница 20: ...ow the set values combustion optimization and acoustic comfort During the first activation of the product unpleasant odours or smoke caused by evaporation or drying of certain materials used may occur...

Страница 21: ...d it to exit the function described in this paragraph To go back to the STAND BY screen press key re peatedly OK OK Edit values by pressing The working logic is the following USER the user reserves th...

Страница 22: ...FUNCTION With the thermostat timer you will be able to set automatic switch on off of the product for each day of the week with 4 independent time intervals available PROGRAMS 1 2 3 4 To enable this...

Страница 23: ...te cleaning of the hopper pellet container has been carried out to remove sawdust accumulated on the base over time For further reference please see chapter Rou tine maintenance of the product Also ch...

Страница 24: ...percentage of 2 for PELLET and 3 for AIR INTAKE was set such kind of setting is needed when combustion is lack ing oxygen and pellets are small in size if compared to the average 2cm pellets OK Selec...

Страница 25: ...is installed has not reached the temperature re quired yet the writing T OFF if room temperature has been reached 11 6 LANGUAGE Depending on the country of destination or the end user this function i...

Страница 26: ...appliance to re establish communication 12 CANALIZATION not supplied with this model Products in our the range can be equipped with two types of canalization single duct canalization or dou ble duct c...

Страница 27: ...he help of an optional ambient probe provided on request of Nobis s r l not supplied as standard OK If canalization temperature management with external thermostat is enabled it is not possible to edi...

Страница 28: ...settings using the remote control but rather using the external thermostat After confirming settings for RIGHT canalization press and then repeat the same procedure for LEFT canalization OK 12 5 SETTI...

Страница 29: ...ION Room setting on MAN The appli ance will only work with the power set for the fireplace it never switch es to savng mode MAN WORK 14 FUNCTIONS OVERVIEW Edit the data highlighted using the keys Conf...

Страница 30: ...prop er combustion While waiting for a technician for safety purpose the appliance switches to saving mode Smoke temperature overheating the appliance switches temporarily to saving mode with ventila...

Страница 31: ...show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 06 FAULTY SMOKE EXTRACTOR No power supply t...

Страница 32: ...ists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN The tank door has not been closed properly during pellet loading phase SOLUTION Check that the pellet tank door has been clo...

Страница 33: ...ING PROCEDURE Open the fire door using the cold lever supplied with the product and Insert the cold lever in the specific compartment as indicated in the figure below 18 CLEANING THE APPLIANCE Before...

Страница 34: ...e type of pellets used or by a non optimal adjustment of the appliance 18 2 CLEANING THE GLASS DOOR To clean the glass use a cotton cloth or kitchen pa per It is recommended to clean the glass using a...

Страница 35: ...ration are summarised below PARTS FREQUENCY Brazier 1 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chamber 2 3 DD Vac...

Страница 36: ...RACTOR GEARMOTOR MECHANICAL CLEANER RESISTOR SWITCH ON MANUAL RESET THERMAL SWITCH 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH FRONT VENTILATION PC CONNECTION technical support only U...

Страница 37: ...Use and Maintenance Manual model B10 V ULISSE 37 ENGLISH MAINTENANCE DATE INTERVENTION CARRIED OUT...

Страница 38: ...Use and Maintenance Manual model B10 V ULISSE 38 ENGLISH NOTES...

Страница 39: ......

Страница 40: ...srl Via Palazzolo N 11 25037 Pontoglio BS Italy www nobisfire it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its produ...

Отзывы: