1.6 LEGAL WARRANTY

To  benefit  from  legal  warranty,  the  user  must 

 

strictly comply with the provisions indicated in this 

manual. In particular, the user will have to:

• always work within the use limitations of the product;

• always carry out routine maintenance;

•  authorize  the  use  of  the  machine  only  to  people 

with proven capacity, attitudes and who are ade-

quately trained for the purpose;

• use original spare parts specifically intended for 

the appliance model in use.

It is also necessary to provide the following:

• fiscal receipt reporting date of purchase;

• a certificate of compliance for the installation of the 

product, issued by authorized staff.

Non-compliance with the provisions contained in this 

manual will imply immediate forfeiture of the 

 

warranty for both the product and any spare parts 

assembled thereafter.

1.7 EXCLUSIONS FROM WARRANTY

The warranty excludes all malfunctions and/or 

 

damage to the appliance resulting from the 

 

following causes:

• damage caused by transport and/or handling;

• all parts resulting as being faulty due to   

   negligence or careless use, wrong 

   maintenance, or installation non-conforming 

to the manufacturer instructions 

(please, refer to the installation and use manual  

   supplied with the appliance);

• further damage caused by wrong intervention 

   by the user in the attempt to solve a preexisting fault;

• aggravated damage caused by further use 

   of the appliance by the user once 

   a fault has occurred;

• in the presence of a boiler, any corrosion, 

   scale or breakages caused by stray 

   current, condensate, abrasion or acidity in the 

   water, scale removal treatments carried out 

   improperly, water shortage, sludge or limescale deposits;

• inefficiency of the chimneys, chimney flues or parts of the   

   system on which the appliance depends;

• damage caused by tampering with the appliance, 

   atmospheric agents, natural disasters, vandalism,   

   electrical discharge, fire, faulty electrical and/or 

   plumbing system.

The following are also excluded from the warranty:

• parts subject to normal wear such as gaskets, 

   glass, coverings and cast iron grates, painted, 

   chrome-plated or gold-plated parts, handles and 

   electrical cables, lights, switch resistor, indicator lights,   

   knobs, and all those parts that can be removed from 

   the fireplace (e.g. refractory, brazier);

• color variations of painted and ceramic parts, 

   as well as ceramic cracks (being natural features 

   of the material and consequent to use of the product;

• masonry works;

• parts of the system (if present) not supplied by 

   the manufacturer;

Therefore, any technical interventions on the product 

for the elimination of the aforementioned defects 

and consequent damages must be agreed with the 

Technical Assistance Center, which reserves the right 

to accept or refuse the relevant assignment and in 

any case will not carry out the task as a guarantee, 

but as technical assistance to be provided under 

the conditions possibly and specifically agreed and 

according to the rates in force for the work to be 

carried out. The user will also be charged for the 

costs that may become necessary to remedy his/

her incorrect technical interventions, tampering or, in 

any case, factors which can be harmful to the  

device and that cannot be attributed to  

manufacturing defects. Without prejudice to the 

limits imposed by laws or regulations, any warranty of 

containment of air and noise pollution is also excluded.

• The product can be used by children over   

   8 years of age and people with reduced 

   physical, sensor or mental capacity, or without 

   experience or the necessary know-how, provided   

   that they are supervised, or have received 

   instructions on the safe use of the appliance and are  

  aware of the dangers an improper use may involve.     

  Children must not play with the appliance.

• Cleaning and maintenance intended to be 

   carried out by the user must not be carried out 

   by children without supervision.

• Do not dry the laundry on the the product. 

• The fuel and other flammable materials must

   be kept at a suitable distance from the product.  

   Fire hazard.

• The product must be electrically connected 

   to a system equipped with a suitable grounding  

   system.

• In the event of a fault in the switch-on system, do not 

   force ignition using flammable material. Consult an   

   authorized technician.

• For non-hermetic products, installation in small rooms  

   and bedrooms is forbidden.

• Installation is forbidden in environments with an 

   explosive atmosphere. 

Содержание B10 V ULISSE

Страница 1: ...EN Installation use and maintenance manual B10 V ULISSE...

Страница 2: ...oduct Please keep the manual in a suitable place after consulting it carefully Improper installation incorrect maintenance and or misuse of the product relieve the Manufacturer of any liability toward...

Страница 3: ...trol keys 16 7 3 Description of remote control display 16 7 4 Flat battery signalling 17 7 5 Icon overview 17 8 Menu browsing 18 9 First start up instructions 18 9 1 Hour date settings 18 9 2 Calibrat...

Страница 4: ...regular basis do not remove or bypass this devices 1 3 IMPROPER USE The product is intended to be used for the purpos es and within the limits for which it was expressly de signed for any other use th...

Страница 5: ...inted chrome plated or gold plated parts handles and electrical cables lights switch resistor indicator lights knobs and all those parts that can be removed from the fireplace e g refractory brazier c...

Страница 6: ...able and reduce the overall efficiency of the system are created Hermetic products can also be installed in the presence of forced ventilation or in premises which can go into negative pressure if com...

Страница 7: ...ian who will provide the purchaser with a Declaration of Conformity for the system and will assume complete responsibility for final installation and resulting good operation of the product In particu...

Страница 8: ...ke outlet must not be more than 3 the changes of direction must not have an angle exceeding 90 a 45 curve is recommended the section must have constant diameter equal to the output of the fireplace up...

Страница 9: ...ate if in contact with flammable parts such as wood etc In both cases please provide with adequate insula tion the space between the chimney flue and the attic 5 It is also recommended to check and co...

Страница 10: ...stem and or make sure the electrical cable to the external socket is placed safely Open the appliance by using the specific handle to be found in the box together with the instruction manual With your...

Страница 11: ...LET LOADING METHODS There are 3 possible solutions to load pellets slide the appliance open standard use the pellet drawer optional use the wall pellet loading system optional SLIDING Open the applian...

Страница 12: ...panel Re tighten the 4 screws back again to fix the drawer 1 2 1 2 HOW TO USE IT 1 2 Use the specific handle supplied to pull out the pellet drawer Start loading pellets dropping it into the hopper u...

Страница 13: ...agraph must be car ried out by authorized technical staff Remember before carrying out any maintenance operation to implement the following precautions all parts of the product must be cold ensure the...

Страница 14: ...CODE ASSIEME MODELLO CODICE FORNITORE 1 N0039 IPAV 111 65 A O 27 11 2019 DENOMINATION Propriet della Societ NOBIS S r l Senza autorizzazione scritta della stessa il presente disegno non potr essere u...

Страница 15: ...he electronic board is waiting for the remote control signal Press the confirmation key on the remote control to make the components communicate with one another A tick sign on the display accompanied...

Страница 16: ...ollows After 20 seconds of inactivity the display on the remote control blacks out and passes to SLEEP mode maintaining the remote connection with the appliance The display will re enable by simply by...

Страница 17: ...us of the appliance see Icons Overview 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display will show a symbol indi cating their limit status maintaining the functions of the remote control ena...

Страница 18: ...ER by pressing Access menu by pressing Scroll entries to SETTINGS and press Access menu by pressing Scroll entries to HOUR DATE by pressing On the HOUR DATE menu entry press The screen to adjust time...

Страница 19: ...n OFF In this case the appliance will manage autonomously only the power to the fireplace Ventilation will remain disabled 9 5 FIREPLACE POWER SETTINGS The fireplace power defines the quantity of heat...

Страница 20: ...ow the set values combustion optimization and acoustic comfort During the first activation of the product unpleasant odours or smoke caused by evaporation or drying of certain materials used may occur...

Страница 21: ...d it to exit the function described in this paragraph To go back to the STAND BY screen press key re peatedly OK OK Edit values by pressing The working logic is the following USER the user reserves th...

Страница 22: ...FUNCTION With the thermostat timer you will be able to set automatic switch on off of the product for each day of the week with 4 independent time intervals available PROGRAMS 1 2 3 4 To enable this...

Страница 23: ...te cleaning of the hopper pellet container has been carried out to remove sawdust accumulated on the base over time For further reference please see chapter Rou tine maintenance of the product Also ch...

Страница 24: ...percentage of 2 for PELLET and 3 for AIR INTAKE was set such kind of setting is needed when combustion is lack ing oxygen and pellets are small in size if compared to the average 2cm pellets OK Selec...

Страница 25: ...is installed has not reached the temperature re quired yet the writing T OFF if room temperature has been reached 11 6 LANGUAGE Depending on the country of destination or the end user this function i...

Страница 26: ...appliance to re establish communication 12 CANALIZATION not supplied with this model Products in our the range can be equipped with two types of canalization single duct canalization or dou ble duct c...

Страница 27: ...he help of an optional ambient probe provided on request of Nobis s r l not supplied as standard OK If canalization temperature management with external thermostat is enabled it is not possible to edi...

Страница 28: ...settings using the remote control but rather using the external thermostat After confirming settings for RIGHT canalization press and then repeat the same procedure for LEFT canalization OK 12 5 SETTI...

Страница 29: ...ION Room setting on MAN The appli ance will only work with the power set for the fireplace it never switch es to savng mode MAN WORK 14 FUNCTIONS OVERVIEW Edit the data highlighted using the keys Conf...

Страница 30: ...prop er combustion While waiting for a technician for safety purpose the appliance switches to saving mode Smoke temperature overheating the appliance switches temporarily to saving mode with ventila...

Страница 31: ...show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 06 FAULTY SMOKE EXTRACTOR No power supply t...

Страница 32: ...ists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN The tank door has not been closed properly during pellet loading phase SOLUTION Check that the pellet tank door has been clo...

Страница 33: ...ING PROCEDURE Open the fire door using the cold lever supplied with the product and Insert the cold lever in the specific compartment as indicated in the figure below 18 CLEANING THE APPLIANCE Before...

Страница 34: ...e type of pellets used or by a non optimal adjustment of the appliance 18 2 CLEANING THE GLASS DOOR To clean the glass use a cotton cloth or kitchen pa per It is recommended to clean the glass using a...

Страница 35: ...ration are summarised below PARTS FREQUENCY Brazier 1 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chamber 2 3 DD Vac...

Страница 36: ...RACTOR GEARMOTOR MECHANICAL CLEANER RESISTOR SWITCH ON MANUAL RESET THERMAL SWITCH 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH FRONT VENTILATION PC CONNECTION technical support only U...

Страница 37: ...Use and Maintenance Manual model B10 V ULISSE 37 ENGLISH MAINTENANCE DATE INTERVENTION CARRIED OUT...

Страница 38: ...Use and Maintenance Manual model B10 V ULISSE 38 ENGLISH NOTES...

Страница 39: ......

Страница 40: ...srl Via Palazzolo N 11 25037 Pontoglio BS Italy www nobisfire it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its produ...

Отзывы: