 WARNING

Before using the electric screwdriver, lock the connector securely for a connection between the electric 
screwdriver and the screw fastening counter.

Since there is a danger of malfunction or electric shock, connect the electric screwdriver to the power supply 
with the screw fastening counter turned OFF.

For the power supply for the screw fastening counter, use the same voltage as the rated voltage of the electric 
screwdriver being used.

The voltage supplied from the electric screwdriver to the screw fastening counter will be the same value as the 
power supply voltage of the screw fastening counter.

Confirm that the power supply of the screw fastening counter is OFF and connect the connection 
cord to the screw fastening counter

Turn ON the power of the screw fastening counter

Changeover switch

 CAUTION

Do not operate the changeover switch while the tool is rotating. Doing so could cause a failure.

When the tool is not used, set the switch to neutral position.

Do not apply a shock (such as dropping) or excessive load to the changeover switch. Doing so could cause a 
failure.

By sliding the changeover switch, you can change 
the rotation direction of the electric screwdriver.
“ - ” means neutral. The electric screwdriver does 
not rotate.

Rotates 
counterclockwise

Rotates clockwise

Basic Operation

Содержание DLV30A06L-SP

Страница 1: ...e Nm Low torque spring 0 4 to 1 6 2 0 to 4 5 3 8 to 7 0 High torque spring 1 2 to 3 0 Free Speed min 1 650 1200 2000 650 1200 650 Please refer to p 6 for details Please read manual carefully before yo...

Страница 2: ...that Can Be Attached 3 3 Part Names 4 SP type 4 SPC type 5 4 Specifications 6 Torque scale and output torque 7 SP type signal specifications 7 5 Preparation 10 Attaching a bit 10 Attaching the suspen...

Страница 3: ...ll Depending on fastening conditions screws may become loose Improper impacts could decrease product life or cause product failure Do not use the tool for anything other than screw tightening It shoul...

Страница 4: ...f the SPC type This tool is only for screw fastening counter DLR5040A WE and DLR5340 WE Use it in combination with the screw fastening counter For how to use the screw fastening counter refer to the i...

Страница 5: ...that Can Be Attached You can identify bits that can be attached based on the alphabet character written to the right of the serial number of the electric screwdriver 1 Serial No 1 Attachable bit shape...

Страница 6: ...it 0 Changeover Switch a Torque Scale standard b Torque Adjustment Ring Model Rubber ring Torque adjustment ring cover Lever start type Push start type DLV30A06L SP AJ DLV30A06P SP AJ Yellow Resin tra...

Страница 7: ...9 Torque Scale standard 0 Torque Adjustment Ring Model Rubber ring Torque adjustment ring cover Lever start type Push start type DLV30A06L SPC AJ DLV30A06P SPC AJ Yellow Resin transparent DLV30A12L SP...

Страница 8: ...5 HEX 6 35 mm or NK31 HEX 5 mm 1 Mass kg 0 7 excluding the power cord Power supply 230 V AC 50 60 Hz Power Consumption W 45 Duty Cycle ON time 0 5 sec OFF time 3 5 sec 1 For details on how to identify...

Страница 9: ...the signal output within the output rating Use of the tool at a voltage or current value above the rating could cause the tool to fail Do not directly connect the relay motor lamp etc to control It co...

Страница 10: ...Do not directly connect the relay motor lamp etc to control It could cause the tool to fail due to surge etc generated from inductive load Before energizing make sure that the signal cables are wired...

Страница 11: ...rned ON while the changeover switch of forward and reverse rotation is at the neutral position When torque up occurs in the reverse rotation the torque up signal is also output Signal cable wiring col...

Страница 12: ...ease the sleeve and make sure the bit does not come off To remove the bit pull out the bit while pulling the sleeve Attaching the suspension bail CAUTION If the suspension bail is pulled forcefully it...

Страница 13: ...is turned there will be no clicking sound Recommended grease separately sold Idemitsu Kosan Co Ltd Daphne Eponex SR No 2 Showa Shell Sekiyu K K Alvania Grease S2 Cosmo Oil Co Ltd DYNAMAX No 2 1 Turn t...

Страница 14: ...Grip body A and the semicircle rib of the frame handle 2 Attach the parts to the positions shown in the following figure 3 Match the rib of the Pistol Grip body B and the groove of the frame handle Ma...

Страница 15: ...e If you are not sure about the grounding of the outlet request an electrical contractor to check if it is grounded When an extension cord is used use a 3 core cord that includes a ground wire SP type...

Страница 16: ...value as the power supply voltage of the screw fastening counter 1 Confirm that the power supply of the screw fastening counter is OFF and connect the connection cord to the screw fastening counter 2...

Страница 17: ...rs Be sure to turn ON the start switch until the electric screwdriver automatically stops Slide the changeover switch to the direction in which you want the tool to rotate and press the start switch t...

Страница 18: ...n the electric driver stops release the start switch Adjusting the output torque WARNING Before adjusting the output torque always turn OFF the power CAUTION The torque scale is a standard The output...

Страница 19: ...increased screws are not tightened Review the screw fastening conditions Also by tightening at low speed it becomes easier to transmit torque Has initial loosening occurred Initial loosening occurs a...

Страница 20: ...nditions Also it differs by the unit p 6 Maintenance and inspection Store the tool according to the following warnings and cautions WARNING Before performing maintenance and inspection always turn off...

Страница 21: ...w head could be damaged or torque may not be transmitted Replace with a new bit Main unit Check for damage cracks or breaks on the main unit Check the screws on the main unit including accessory Pisto...

Страница 22: ...unter DLR5040A WE DLR5340 WE Dedicated to SPC type Counter for prevention of human error and for management of fastening 100 V AC 240 V AC SPC extension cable 3 m Dedicated to SPC type Cord that exten...

Страница 23: ...5 4 5 42 DIA 42 DIA Front view DLV30A06L SP AJ SPC AJ DLV30A12L SP AJ SPC AJ DLV30A20L SP AJ SPC AJ Front view DLV30A06P SP AJ SPC AJ DLV30A12P SP AJ SPC AJ DLV30A20P SP AJ SPC AJ Side view Common to...